Download Print this page

Awoco RH-C06-A-FC Owner's Manual

6" height under cabinet all-in-one series

Advertisement

Quick Links

awoco.com
Model: RH-C06-A-FC
Manual Revision: 2024A
6" Top
Round Adapter
Air Damper
3-1/4" x 10" Top
Rectangular Adapter
3 adapters & 1 remote control are included.
Note
The Touch Control Panel is covered by
a transparent film. Peel it off from the
corner if needed.
* Unpack & Check for Shipping Damages *
* Test Run Before Installation *
Range Hood
OWNER'S
MANUAL
6" Height Under Cabinet
All-in-One Series
Caution !
Make sure the air damper can
open freely after the installation.
3-1/4" x 10" Rear
Rectangular Adapter

Advertisement

loading
Need help?

Need help?

Do you have a question about the RH-C06-A-FC and is the answer not in the manual?

Questions and answers

Summary of Contents for Awoco RH-C06-A-FC

  • Page 1 Range Hood awoco.com OWNER'S MANUAL Model: RH-C06-A-FC Manual Revision: 2024A 6" Height Under Cabinet All-in-One Series Air Damper Caution ! Make sure the air damper can open freely after the installation. 6" Top 3-1/4" x 10" Top 3-1/4" x 10" Rear...
  • Page 2: Installation Overview

    Screws. on the installation and may not include solutions for all possible issues that may occur. 2 PEOPLE ARE REQUIRED FOR THE INSTALLATION. In case of this manual destroyed or lost, please visit https:/ /awoco.com and download a digital version.
  • Page 3: Table Of Contents

    Important Safety Instructions Installation Preparations Venting Requirements Venting System Setup Duct Run Calculation Chart Electrical Requirement Installation Installing the Range Hood Connecting the Vent System Electrical Connection Installing the Baffle Filters Completing the Installation Range Hood Use Range Hood Control Panel Range Hood Care Clean the Exterior Surfaces Clean or Replace the Baffle Filters...
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK low or medium settings. OR PERSONAL INJURY, PLEASE READ THE • Always turn the hood ON when cooking at FOLLOWING CAREFULLY BEFORE ATTEMPTING high heat or when flambeing food (i.e. Crepes TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN Suzette, Cherries Jubilee, Peppercorn Beef THE RANGE HOOD:...
  • Page 5: Installation Preparations

    INSTALLATION PREPARATIONS Venting Requirements DO NOT • Have the venting system go vertically from the • End the venting system in an enclosed area range hood to the roof if possible. indoors. • Have 24"-30" distance between the cooktop • Use plastic vent.
  • Page 6: Duct Run Calculation Chart

    INSTALLATION PREPARATIONS Rear Venting in-Wall Exhaust Duct Damper Rear Cabinet Adapter Range Hood Caution ! • The fully opened Air Damper might block the air IMPORTANT! flow. Stove Top • Remove the Air Damper first before connecting the duct Observe all governing codes and ordinances. to the Rear Adapter.
  • Page 7: Installation

    INSTALLATION This range hood series can be: the bottom of the cabinet through the knockout holes shown below: • Installed under the cabinet ONLY. 1. Installing the Range Hood Under the Cabinet • For installing under the cabinet with recessed bottom, attach a 4"...
  • Page 8: Installing The Baffle Filters

    INSTALLATION • In case of a direct connection to the house 5. Installing the Oil Collector wiring is preferred, do the following: • Disconnect the power. • Follow the instruction in Page 10 to install the • Cut off the plug from the power cord. Oil Collector.
  • Page 9: Range Hood Use

    RANGE HOOD USE Range Hood Control Panel operations within 5 seconds. When the Delayed Auto Shut Off fuction is activated • Remote Delayed Control Auto while the blower is running, a countdown timer will Sensor Shut Off Light show up in the LCD Display. Light - 2 Light Levels Touch the Light button once and the lamps will turn •...
  • Page 10: Range Hood Care

    • This range hood uses 12V, 2W LED. half an hour, then wipe the filter clean. Repeat Contact Awoco customer service to get the these steps until there's no oil residue remains. replacement LED lights. •...
  • Page 11 RANGE HOOD CARE Remove Baffle Filters • Reach into the Hood Unit and push the Lamp out from the inside of the Hood Unit. Push the lamp out • Disconnect the wires. • Connect the wires to the new Lamp. •...
  • Page 12: Range Hood Troubleshooting

    RANGE HOOD TROUBLESHOOTING Before Calling for Service Issue Possible Cause / Solution If the air damper does not open freely when the hood turns on, the smoke can't be sucked out. The air damper does not open after • Remove the duct attached to the hood, clear any debris that installation are blocking the air damper, and make sure that the air damper can open freely before reconnecting the duct.
  • Page 13: Warranty

    • Repair parts or replacement products will be provided by Awoco, free of charge, on an • Contact us at 1-888-412-3428, between 10 exchange basis, and will be either new or AM and 5 PM, Monday - Friday, Pacific Time.