INSTALLATION PREPARATIONS
Electrical Requirements:
A 120V, 60Hz., AC only, 3A fused electrical
circuit is required.
Wire sizes and connections must conform
with the power rating of the range hood and
all applicable codes and standards.
DO NOT have a fuse in the neutral or ground
circuit.
The 3-prong outlet should be grounded. If the
power cord plug is not used, the power cord's
green wire should be connected to ground.
Check with a qualified electrician if you are
not sure that the range hood is properly
grounded.
DO NOT ground to a gas pipe.
The range hood must be connected with
copper wire/plug only.
The range hood should be connected directly
to the fused disconnect box (or circuit breaker)
through flexible armored or non-metallic
sheathed copper cable. ETL listed strain relief
must be provided at each end of the power
supply cable.
Mounting Height Recommendations:
Traditional Installation Mounting Height
6
Horizontal Ceiling Mount
The recommended mounting height for ceiling
mount installation is 7 to 8 feet.
Identify the Vent In and Out Openings
on the Blower Unit
The Blower Unit has 2 vent openings on 2
opposite sides. One side with just a Vent
Opening and the other side with a Black
Speed Control Box and a Vent Opening.
Blower Unit Installed Vertically
Connection Box
Vent in from the
Hood Unit
Blower Unit Installed Horizontally
Vent in from the
Hood Unit
Vertical Ceiling Mount
Vent out to the
Roof
Vent out to
the Roof