Chapter V Run and Maintain
The correct operation and maintenance of the motion controller can not only
guarantee and extend the life cycle of the equipment itself, but also take technical
management measures according to the pre-specified plan or the corresponding
technical conditions to prevent equipment performance degradation or reduce the
probability of equipment failure.
5.1. Regular Inspection and Maintenance
The working environment has an impact on the controller. Therefore, it is usually
inspected regularly based on the inspection cycle of 6 months to 1 year. The inspection
cycle of the motion controller can be appropriately adjusted according to the surrounding
environment to make it work within the specified standard environment.
Check item
power supply
Check whether the voltage is rated
Whether the ambient temperature is
within the specified range (when
installed
temperature inside the cabinet is the
ambient temperature)
Whether the ambient humidity is
within the specified range (when
installed in the cabinet, the humidity
in the cabinet is the ambient
surroundings
humidity)
Is there direct sunlight
With or without droplets of water, oil,
chemicals, etc.
Whether there is dust, salt, iron
filings, dirt
Whether there is corrosive gas
Whether there are flammable and
explosive gases or articles
Check content
in
the
cabinet,
Inspection standards
DC 24 V ( -10%~10%)
the
-10° C - 55° C
10%-95% non-condensing
No
No
No
No
No