Cause
F01512
An attempt has been made to
establish an conversion factor for
scaling which is not present
F01662
CU hardware fault
F30022
Power Module: Monitoring U
F30052
Incorrect Power Module data
F30053
Error in FPGA data
F30662
CU hardware fault
F30664
CU power up aborted
F30850
Software fault in Power Module
Table 12- 13 The most important alarms and faults
Number
Cause
F01018
Power-up aborted more than
once
A01028
Configuration error
F01033
Unit switchover: Reference
parameter value invalid
F01034
Unit switchover: Calculation of
the parameter values after
reference value change
unsuccessful
F01122
Frequency at the probe input too
high
A01590
Motor maintenance interval
lapsed
A01900
PROFIBUS: Configuration
telegram faulty
A01910
Fieldbus SS setpoint timeout
F01910
A01920
PROFIBUS: Cyclic connection
interrupt
SINAMICS G120C frequency converter
Operating Instructions, 03/2012, FW V4.5, A5E02999804B AB
Remedy
Create scaling or check transfer value.
Switch CU off and on again, upgrade firmware, or contact technical
support.
Check or replace the Power Module.
CE
Replace Power Module or upgrade CU firmware.
Replace the Power Module.
Switch CU off and on again, upgrade firmware, or contact technical
support.
Switch CU off and on again, upgrade firmware, or contact technical
support.
Replace Power Module or contact technical support.
Remedy
1. Switch the module off and on again.
2. After this fault has been output, the module is booted with the factory
settings.
3. Recommission the converter.
Explanation: Parameterization on the memory card has been created with a
different type of module (order number, MLFB)
Check the module parameters and recommission if necessary.
Set the value of the reference parameter to a value other than 0.0 (p0304,
p0305, p0310, p0596, p2000, p2001, p2002, p2003, r2004).
Select the value of the reference parameter so that the parameters involved
can be calculated in the per unit notation (p0304, p0305, p0310, p0596,
p2000, p2001, p2002, p2003, r2004).
Reduce the frequency of the pulses at the probe input.
Carry out the maintenance.
Explanation: A PROFIBUS master is attempting to establish a connection
with a faulty configuration telegram.
Check the bus configuration on the master and slave side.
The alarm is generated when p2040 ≠ 0 ms and one of the following causes
is present:
The bus connection is interrupted
The MODBUS master is switched off
Communications error (CRC, parity bit, logical error)
An excessively low value for the fieldbus monitoring time (p2040)
Explanation: The cyclic connection to PROFIBUS master is interrupted.
Establish the PROFIBUS connection and activate the PROFIBUS master
with cyclic operation.
Alarms, faults and system messages
12.4 List of alarms and faults
289