MULTI-AMPLITUDE LFO CONTROL
●
Set channels A, B, C, and D to LFO mode
(triangle or any shape: SHIFT+A/B/C/D/E)
●
Set META IN for A, B, C, and D to VCA mode
(select channel and press SHIFT+MODE)
●
Turn off META IN for channels E and F
(select channel and long-press SHIFT+MODE)
●
Set channel F to CV mode
●
Patch channel F into META IN
Use the channel F output to set the amplitude of all A, B, C,
and D LFOs.
LFO
LFO
VCA
VCA
L
E
N
G
T
H
LFO
LFO
VCA
VCA
CV
PATCH