EXTERNAL CLK MODE
The internal clock is ignored when a jack is plugged into CLK IN.
Select the external clock multiplier/divider factor by holding
SHIFT and pressing one of the channel buttons A/B/C/D/E/F:
A – 8 divider
substep 6 divider
B – 4 divider
substep 3 divider
C – 2 divider
D – normal 1x
E – 2x multiplier
substep 3x multiplier
F – 4x multiplier
Hold SHIFT and press CLK (+) or MUTE (-) to browse the
substeps with odd numbered divider/multiplier factors.
NOTE: The multiplier/divider change may take a few clock
cycles to finish, since the module is first completing the current
multiplication/division cycle.
Turn the RATE knob to select a multiplier/divider.
Hold REC and tap SHIFT to enter the multiplier/divider factor
by tapping as in the internal clock mode(TAP Tempo). The clock
rate will be multiplied by 4 and the closest multiplier/divider will
be selected.
/2
/3
/4
/6
/8
CLK DIVIDER/MULTIPLIER