INPUT CALIBRATION

Hold MODE at power-up to enter the User calibration mode.
To calibrate any of the CV inputs (META IN, IN E or IN F), use
the output of a selected channel and plug it into any of the
three CV inputs. These inputs will be calibrated automatically,
and the REC light will blink to confirm.
Hold the MODE button for over 5 seconds to leave User
calibration mode. The calibration is stored in memory.
Boot settings

FORMAT MEMORY

Hold BANK on power-up. All the custom banks, channels and
clock settings are erased.

FACTORY CALIBRATION

Hold BANK+MODE on power-up. Factory calibration is cleared.
Now, you need to calibrate the unit to use the module again.
Channel A is being calibrated automatically. Wait for the blinking.
When the blinking starts, Neo Trinity is waiting for you to:
1.
Connect Channel A to META IN
2.
Unplug the cable from META IN and plug it into IN E
3.
Unplug the cable from IN E and plug it into IN F
4.
Unplug the cable from Channel A and plug it into Channel B
5.
Unplug the cable from Channel B and plug it into Channel C
6.
Unplug the cable from Channel C and plug it into Channel D
7.
Unplug the cable from Channel D and plug it into Channel E
8.
Unplug the cable from Channel E and plug it into Channel F
The device is now calibrated and continues into Factory
test Mode.
Hold MODE or power-cycle the module to exit the test mode.