FACTORY TEST MODE

Hold SHIFT on power-up to enter the Factory test Mode, where
you can test the user interface. Most inputs and outputs are
already tested during the Factory calibration.
When you press a button, the light close to the button should
temporarily turn ON; the REC and CLK OUT lights should turn
ON when the REC button is pressed. Pressing the MODE button
cycles through the Mode lights.
RATE knob controls the RATE light below it and cycles all
outputs between -5V and 5V in 1V steps (light intensity and
color varies accordingly).
CLK IN can be tested by patching a cable from CLK OUT into
CLK IN – when CLK IN receives a clock signal (by tapping REC),
the CLK light will come ON. The RESET input can be tested in
the same way, by patching a cable from CLK OUT into it. MUTE
light goes ON when the RESET input receives a signal.
NOTE: When the test mode is starting, the exact firmware
build version is shown as a right-aligned binary number (A-F).
Exit the test mode by long pressing MODE or power cycling
the module.