! POWER !
Before connecting the ribbon cable to this module, disconnect
your system from power! Double-check the polarity of the
ribbon cable and that it is not misaligned in any direction. The
red wire should match the -12V rail both on the module and the
bus board.
! PLEASE MAKE SURE OF THE FOLLOWING:
●
you have a standard pinout eurorack bus board
●
you have +12V and -12V rails on your bus board
●
the power rails are not overloaded by current
●
this module requires current: +12V: <100 mA; -12V: <35 mA
Although there are protection circuits on this device, we do not
accept any responsibility for damages caused by the wrong
power supply connection.
After you've connected everything, double-checked it, and
closed your system (so no power lines can be touched by hand),
turn on your system and test the module.