Malfunctions
7.1 Fault elimination
– Screen out of order: The displayed error code (for example, #40-02-00) can only be
Figure 7-2  Screen out of order
– Flash codes of the LED status display (see Status indicators (Page 70))
– Error message via OCPP to the backend (see OCPP messages (Page 84))
2. You can find a selection of possible causes of faults and possible remedies in the table
below.
3. If you are unable to rectify the fault yourself, contact the operator's service hotline.
Cause
Vehicle not connected
Communication error (Mode 3)
Cable lock error
Cable release fault
82
used for diagnostics and fault clearance (e.g. with the help of the Service hotline).
Remedied by
Operator
Operator
Operator
Operator
Solution
Connect the charging cable to the vehicle.
Check the charging cable.
Disconnect the vehicle from the charging station and
reconnect the vehicle.
Check the vehicle.
Check the charging cable.
Check the charging station (plug and cable).
Disconnect the charging cable and reconnect it.
Check that the plug is not soiled (e.g. due to snow or
icing).
Check the locking mechanism (or controller).
Carefully plug the charging cable into the socket.
Disconnect the cable again.
Check the locking mechanism (or EVSE controller).
SICHARGE Operating instructions, ERK
Operating Instructions, 02/2023, A5E48571690-AE