A list of order options can be found in section Options available for orders (Page 111) in the
appendix.
Technical specifications
Designation
Display
Supply voltage
Connection frequency
Maximum connected power
Maximum charging capacity per charging point
Load management acc. to maximum infeed, chronological prior
itization
Supported networks (local requirements to be clarified on site)
Maximum cross-section for cable
Weight (standard model)
Dimensions (H x W x D) in mm
Ambient temperature operating range
Humidity
Ambient air pressure
Degree of protection (IP)
Intrinsic consumption in standard version
Accuracy class energy counter
SIM card (recommended data volume)
Standards and legal bases:
EN 61851-1:2011
EN 61851-22:2002
EN 61000-6-3:2007+A1:2011
EN 61000-3-11:2000
EN 61000-3-12:2011
EN 61000-6-1:2007
IEC 62196-2
REA document 6-A / PTB-A 50.7 Legal reference to the Measure
ment and Calibration Act of 25 July 2013
1
= For 1-phase charging with fixed charging cable, the operator must limit the output power to
3.7 kW
2
= If video functions are used, the data volume may have to be increased
SICHARGE Operating instructions, ERK
Operating Instructions, 02/2023, A5E48571690-AE
Technical specifications
SICHARGE CC AC22
7" LED
400 V AC ± 10%
3-phase
N+PE
50 Hz
63 A / phase
22 kW
1
6 ... 63 A
TN-C / TN-S
TN-C-S/TT
2
35 mm
75 kg
1700 x 390 x 194
-25 ... 50 °C
5 ... 95%
860 ... 1060 hPa
IP 54
25 W
Class A
2
500 MB / month
●
105