INFORMATION FOR REPLACING THE
5. Loosen the air bleeding screw F on fuel filter bracket
B.
The air inside the circuit and the filter will begin to
escape from the screw G.
6. Tighten the bleeding screw F (tightening torque of 1.5
Nm) when the fuel begins to flow.
Warning
Check that the fuel supply pump filter is present, and
replace if necessary.
1. Release the clamp D.
2. Demount the hose E.
3. Unscrew the filter G from the pump Q.
4. Screw the new filter G onto the pump Q (tightening
torque 20 Nm).
5.
Connect the hose E to the filter G and fasten with the
clamp D.
NOTE: Click on the icon to play the procedure.
FUNCTIONAL UNITS