8
Fig. 8.26

8.7 Oil pump check

8.7.1 Dimensional and visual check
Perform the operations described in
Measure clearance value B between the rotor teeth, the
value of allowable wear is MAX 0.28 mm.
Clean all the components thoroughly, check that the work
surfaces C of the rotors and pump body are not worn.
Important
Should the results from checks carried out not be in
accordance with the conditions described, replace
the timing system carter together with the oil pump.
On assembly, references A must be visible.
8.7.2 Check rotors clearance
Important
Replace carter R complete with its oil pump, if there are signs
of wear in area P of surface Q (Fig. 8.32 - 8.32a).
Measure values G and H (Fig. 8.30).
Measure values L, M and N (Fig. 8.31).
According to the values measured, calculate the clearance
between G and H, L and M and L and N which are to
observe the values in Tab. 8.13.
EN
108
INFORMATION ABOUT OVERHAULING
Par.7.8.1 and Par.7.8.4.
Fig 8.28
Fig 8.29
Fig 8.30

Advertisement