5.6

Wall mounting

Installation
Figure 5-7
To mount the device on a wall, you require the following:
• 2 wall plugs with a diameter of 6 mm and a minimum length of 35 mm.
• 2 countersunk head screws with a diameter of 3.5 mm to 4 mm and a minimum length of
70 mm.
Note
The wall mounting must be capable of supporting four times the self-weight of the device, but
at least 50 N.
To mount the device on a wall, follow the steps below:
1. Prepare the drill holes. Use suitable dowels for walls made of masonry or concrete.
2. Secure the device to the wall with two screws.