Siemens SCALANCE XCM-100 Equipment Manual page 56

Simatic net network components media converter
Hide thumbs Also See for SCALANCE XCM-100:
Table of Contents

Advertisement

Technical specifications
8.1 Technical specifications of SCALANCE XCM102
Technical specifications
Ambient temperature
1)
Relative humidity
Enclosure, dimensions and weight
Design
Enclosure material
Degree of protection
Dimensions (W x H x D)
Weight
Installation options
Mean time between failure (MTBF)
MTBF (EN/IEC 61709; 40 °C)
Derating
1)
The derating values depend on the maximum ambient temperatures during operation up to
2000 m.
Degree of protection
2)
The degree of protection was not examined in the context of FM certification.
 Transmission speed
3)
The transmission speed is based on the plugged SFP transceiver.
56
When operating with plug-in trans‐
ceivers of the types:
SFP991-1
SFP991-1LD
SFP992-1
SFP992-1LD
Up to 2000 m above sea level
When operating with other plug-in
transceivers up to 2000 m above sea
level
With operation between 2000 m and
3000 m above sea level
With operation between 3000 m and
4000 m above sea level
During storage
During transportation
During operation, at 25 ℃
Compact
Polycarbonate (PC-GF10)
IP 20
2)
35 x 147 x 123 mm
 220 g
DIN rail mounting
Installation on an S7-300 mounting rail
Installation on S7-1500 mounting rail
Wall mounting
> 152 years
During operation in horizontal installation po‐
sition of the rack:
-40 °C to +70 °C
During operation in a different installation po‐
sition:
-40 °C to +60 °C
During operation in horizontal installation po‐
sition of the rack:
-40 °C to +60 °C
During operation in a different installation po‐
sition:
-40 °C ... +50 °C
The maximum ambient temperature is reduced
by 5 °C
1)
The maximum ambient temperature is reduced
by 10 °C
1)
-40 °C ... +85 °C
-40 °C ... +85 °C
≤ 95% without condensation
SCALANCE XCM-100 Media Converter
Equipment Manual, 12/2023, C79000-G8976-C659-03

Advertisement

Table of Contents
loading