4.4

Wall mounting

To mount the device on a wall, you require the following:
● 4 wall plugs, 6 mm in diameter and 30 mm long
● 4 screws 3.5 mm in diameter and 40 mm long
To mount the device on a wall, follow the steps below:
1. Prepare the drill holes for wall mounting. For the precise dimensions, refer to the section
"Dimension drawings (Page 51)".
2. Fit the connectors for the power supply. See also section "Power supply (Page 33)".
3. Fit the connectors for the signaling contacts. See also section "Signaling contacts
(Page 35)".
4. Insert the terminal blocks into the sockets on the device.
5. Screw the device to the wall.
Note
The wall mounting must be capable of supporting at least four times the weight of the device.