Bosch GV2 Series Owner's Manual

Bosch GV2 Series Owner's Manual

Supplement
Hide thumbs Also See for GV2 Series:

Advertisement

GV2 Series Control Panels
Owner's Manual
EN
Supplement

Advertisement

Table of Contents
loading

Summary of Contents for Bosch GV2 Series

  • Page 1 GV2 Series Control Panels Owner's Manual Supplement...
  • Page 2 GV2 Series Control Panels | Owner's Manual Supplement System Requirements Minimum system requirements for Classification in accordance with ANSI/SIA CP-01-2000: UL Listed and Classified control unit Model D9412GV2, D7412GV2, or D7212GV2 UL Listed and Classified keypad Model D1256, D1257, D1260, D1255, D1255R, or D1255 RW...
  • Page 3: Table Of Contents

    GV2 Series Control Panels | Owner's Manual Supplement Contents Introduction............... 5 General Commands ............5 Two-Man Rule................5 2.1.1 Description ................. 5 2.1.2 Using the Two-Man Rule ............5 Early Ambush ................6 2.2.1 Description ................. 6 2.2.2 Using Early Ambush ..............6 Easy Exit Control ...............
  • Page 4 GV2 Series Control Panels | Owner's Manual Supplement 2.10.1 Description ................18 2.10.2 Using DEL USER ? ..............18 2.11 Add/Change User - [COMMAND 56] ........19 2.11.1 Description ................19 2.11.2 Using Add User ? ..............19 SIA CP-01 Compliance Information .........22 System Requirements..............
  • Page 5: Introduction

    GV2 Series Control Panels | Owner's Manual Supplement 1.0 Introduction This document supplements the Security System Owner’s Manual (P/N: 71-06633-000) with the features for the GV2 Series. The instructions for the commands listed in this document replace those commands in the Security System Owner’s Manual. Refer to the Owner’s Manual for the operation of your new security system...
  • Page 6: Early Ambush

    GV2 Series Control Panels | Owner's Manual Supplement Early Ambush 2.2.1 Description Early Ambush adds an extra step to the disarming process by requiring the entry of an additional passcode to confirm that the area is secure. The second passcode can be same as the first or different, depending upon the configuration.
  • Page 7: Easy Exit Control

    Easy Exit Control 2.3.1 Description The GV2 Series control panels change from one armed state to another armed state without disarming. The Easy Exit Control feature decreases the number of keystrokes and simplifies system operation. This feature is available by default and is always on.
  • Page 8: Passcode Follows Scope

    GV2 Series Control Panels | Owner's Manual Supplement Passcode Follows Scope 2.4.1 Description The Passcode Follows Scope feature is an optional arming and disarming restriction that can be enabled on keypads with access to multiple areas. When this feature is set to No, the keypad restricts Passcode Arming and Passcode Disarming to the home area of the keypad.
  • Page 9: Passcode-Controlled Menu

    GV2 Series Control Panels | Owner's Manual Supplement Passcode-Controlled Menu 2.5.1 Description When enabled, the system prompts users to enter a passcode before viewing the keypad menu. The system shows the user the menu options allowed according to their authority level, thereby providing users only pertinent commands and functions.
  • Page 10: Walk Tests

    GV2 Series Control Panels | Owner's Manual Supplement Walk Tests 2.6.1 Description The D9412GV2, D7412GV2, and D7212GV2 have three Walk Test menus that allow the user to test various points that are within the scope of the keypad without sending a report to the central station.
  • Page 11: Table 2: Hardware States Of Points

    GV2 Series Control Panels | Owner's Manual Supplement 4. Press the [ENT] key to activate the selected walk test function. The keypad shows the number of testable points within the scope of the keypad: ### PTS TO TEST 5. Press the [NEXT] key to see VIEW UNTESTED? 6.
  • Page 12: Door Activated Custom Function

    GV2 Series Control Panels | Owner's Manual Supplement 5. Press the [View untested Pts >] soft key to see ### PTS UNTESTED. 6. Press the [Next Pt >] soft key to view the first or next untested point: [Point Text]...
  • Page 13: Access Level Control

    GV2 Series Control Panels | Owner's Manual Supplement Access Level Control 2.8.1 Description Use this function to manually enable or disable access authority levels assigned to users. This function can be used to disable a user’s access level temporarily instead of deleting and adding the user.
  • Page 14: Door Control

    GV2 Series Control Panels | Owner's Manual Supplement 4. Press the [Change Level ? >] soft key. ACCESS LEVEL CTL appears, indicating that you are affecting the authority levels of cards or tokens and not passcodes. 5. ENTER LEVEL: appears. Enter the access authority level number and press [ENTER].
  • Page 15: Cycle Door

    GV2 Series Control Panels | Owner's Manual Supplement 7. The first sub-function that appears is CYCLE DOOR?. You can cycle through the three sub-functions by pressing [PREV] and [NEXT]. On a D1260 Keypad 1. Ensure that the display shows idle disarmed text.
  • Page 16: Unlock Door

    GV2 Series Control Panels | Owner's Manual Supplement 2. Enter the number of the door to cycle then press [ENT]. This door cycles and the display changes to reflect the new status of the doors. For example, to cycle Door 3, at the CYCLE DOOR 1 2 3 4 5 6 7 8 prompt, press [3], then press [ENT].
  • Page 17 GV2 Series Control Panels | Owner's Manual Supplement 3. Enter the number of the door to secure then press [ENT]. This door secures, and the display changes to reflect the new status of the doors. For example, to secure Door 5, press [5], then press [ENT] at the following prompt: SECURE DOOR 1 2 3 4 5 6 7 8 The display shows SECURE DOOR 1 2 3 4 X 6 7 8.
  • Page 18: Delete User [Command 53]

    GV2 Series Control Panels | Owner's Manual Supplement 2.10 Delete User [COMMAND 53] 2.10.1 Description Use this function to delete a personal passcode from your system without assistance from your security company. You must know the user number for the passcode you want to delete.
  • Page 19: Add/Change User - [Command 56]

    GV2 Series Control Panels | Owner's Manual Supplement 2.11 Add/Change User - [COMMAND 56] 2.11.1 Description Use this function to add or change a passcode or card without assistance from your security company. Before adding or changing a passcode or card, you must know which user numbers are available, the authority level you want to assign to the new user, and the areas in which the passcode or card are valid.
  • Page 20 GV2 Series Control Panels | Owner's Manual Supplement For systems with access control, the following prompts are available: ADD CARD?, CHANGE CARD?, and SUB USER ID?. Refer to Systems With Access Control on page 20 for details. The system does not accept a passcode that is within two digits of an existing passcode.
  • Page 21 GV2 Series Control Panels | Owner's Manual Supplement SUB USER ID? 1. At the SUB USER ID? prompt, press [ENT]. 2. SUB USER #? appears. Enter 1, 2, or 3 for the desired Sub- User and press [ENT]. 3. PRESENT CARD appears. Present the card or token at the reader and wait for the tone.
  • Page 22: Sia Cp-01 Compliance Information

    GV2 Series Control Panels | Owner's Manual Supplement 3.0 SIA CP-01 Compliance Information Warning: The default programming for the control panel includes a 30-second communication delay for alarms on non-fire zone types. It can be removed (or increased to 45 sec) at the option of the end user in consultation with the installer.
  • Page 23: User-Caused False Alarms, Arming The System

    GV2 Series Control Panels | Owner's Manual Supplement User-Caused False Alarms, Arming the System 3.3.1 Exit Time Defaults The SIA standard calls for Exit Time to range from 45 sec to at least two min (not to exceed 255 sec).
  • Page 24: Master Arm No Exit Feature (Unvacated Premises)

    GV2 Series Control Panels | Owner's Manual Supplement 3. The user does not return to stop Entry Delay. The Entry Delay time expires. 4. The control panel starts the alarm transmission sequence, accompanied by an Exit Error report. 3.3.5 Master Arm...
  • Page 25: Arming And Disarming With Keyswitches

    GV2 Series Control Panels | Owner's Manual Supplement Arming and Disarming with Keyswitches Arming Beeps and Flashes The SIA standard requires that the control panel provide a means to annunciate a change in arming state made from a Keyswitch. The Alarm Bell output pulses on twice when a user disarms with a remote device.
  • Page 26: Alarms Acknowledged Within The Abort Window

    GV2 Series Control Panels | Owner's Manual Supplement 3.6.3 Alarms Acknowledged within the Abort Window If the end user acknowledges an alarm within the Abort Window: The alarm output is silenced. No alarm, restoral, or cancel reports are sent. No alarm, restoral, or cancel reports are entered in the control panel event log.
  • Page 27 GV2 Series Control Panels | Owner's Manual Supplement Notes Bosch Security Systems, Inc. | 2/07 | F01U063791-01...
  • Page 28 Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450-9199 Customer Service: (800) 289-0096 Technical Support: (888) 886-6189 © 2007 Bosch Security Systems F01U063791-01...

Table of Contents