Chroma 63200 Series Operation & Programming Manual page 160

High power dc electronic load
Hide thumbs Also See for 63200 Series:
Table of Contents

Advertisement

High Power DC Electronic Load 63200 Series Operation & Programming Manual
12.3.5.1 Checking for CC Dynamic Low Range
A.
First, press CC and DYNA., and then press RANGE to select CC Dynamic Low range.
The LCD screen shows:
B.
Set the DC voltage of the model 63201~63212 to about 10V and the current greater than
the value listed in Table 12-12.
Model
CCDL1(A) CCDL2(A)
63201
63202_500V
63202_600V
63203
63204_500V
63204_600V
63205
63206
63207
63208
63209
63210_500V
63210_600V
63211
63212
12.3.5.2 Checking for CC Dynamic High Range
A.
First press CC and DYNA., and then press RANGE to select CC Dynamic High range.
The LCD screen shows:
B.
Set the DC voltage of the model 63201~63212 to about 10V and the current greater than
the value listed in Table 12-13.
Model
CCDH1(A) CCDH2(A)
63201
63202_500V
63202_600V
63203
63204_500V
63204_600V
12-14
CCDL1:
CCDL2:
Table 12-12
30
0
5
0.5
5
0.5
60
0
10
1.25
10
1.25
18
1.8
60
10
30
3
60
10
100
10
15
5
15
1.2
30
1
30
1
CCDH1:
CCDH2:
Table 12-13
60
0
50
5
50
5
200
0
100
12.5
100
12.5
0.000A
0.000A
T1(ms)
T2(ms)
0.5
0.5
0.2
0.2
0.2
0.2
0.5
0.5
0.2
0.2
0.2
0.2
0.1
0.1
0.5
0.5
0.1
0.1
0.5
0.5
0.5
0.5
1.2
0.2
1
1
1
1
1
1
0.000A
0.000A
T1(ms)
T2(ms)
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
SRR (A/us) SRR(A/us)
1.25
1.25
0.18
0.18
0.18
0.18
2.5
2.5
0.35
0.35
0.35
0.35
0.675
0.675
2.5
2.5
1.35
1.35
2.5
2.5
4.5
4.5
0.5
0.5
0.115
0.115
0.5
0.5
0.5
0.5
SRR (A/us) SRR(A/us)
2.5
2.5
1.8
1.8
1.8
1.8
8.3
8.3
3.5
3.5
3.5