Run Vhf Comm Amplitude Modulation (Am) Generate - Viavi AVX-10K Operation Manual

Flight line test set
Hide thumbs Also See for AVX-10K:
Table of Contents

Advertisement

Chapter 7 Radio Test (COMM)
VHF COMM Amplitude Modulation (AM)
Power Meter Mode
Press the RUN button and the AVX-10K will measure the incoming signal and display
Frequency, Modulation, and Peak or Average Power values when directly connected to
the UUT. When running, the Measurement Hold softkey will be displayed. Press the
Measurement Hold softkey to lock in the reading. Press the Save Settings button to save
the measured values.

7.3.2 Run VHF COMM Amplitude Modulation (AM) Generate

The main screen of the COMM AM Generate application also contains configurable
parameters. These configurable fields have a blue background.
Rev 004
7 - 6
Table 7-2 VHF COMM Amplitude Modulation (AM) Receive Settings
Setting
Frequency
When Frequency Input Type is set to PRESET, allows selection
between 118, 137, 156 MHZ (VHF) and 225, 312, 400 MHz
(UHF)
When Frequency Input Type is set to CHANNEL, allows selection
between 10 MHz and 400 MHz in steps defined by the Channel
Frequency Step (minimum 0.025 MHz) available by selecting the
middle of the button.
When Frequency Input Type is set to VAR, allows selection
between 10 MHz and 400 MHz in steps defined by the Channel
Frequency Step (minimum 0.010 MHz) available by selecting the
middle of the button.
Toggles between ON and OFF
Peak Hold
Toggles between PEAK and AVERAGE
AVX-10K Operation Manual