System Care

NOTE:
*
If you have not read and truly understood this manual, DO NOT operate this equipment.
If the equipment fails or experiences other exceptional circumstances, the bypass valve can always be
closed, allowing tap water into the home without interrupting general water usage. (Refer to page 15.)
IMPORTANT!
!
The condition of the water softener must be checked regularly.
Users should inspect:
A. Whether there is any leakage in the pipeline.
B. Whether the drain line is blocked. If so, clear it.
C. Whether the brine tank is vertical. If not, then straighten it.
D. Check the salt levels in the brine tank weekly, add additional salt as needed. On average 2 new bags will be
needed per month.
Use softening salt pellets for the water softener and avoid using small granular salt.
Once the water softener has been stopped for a period of time, a regeneration operation should be added to ensure
the quality of the softened water before reuse.
If water consumption increases significantly (relative to normal usage) or the hardness of raw
water increases, the number of regenerations should be adjusted. (See page 22 for calculation.)
The service life of the cation exchange resin is five (5) to ten (10) years, depending on water usage and quality.
The system should be serviced after five (5) years if a decrease in performance is noticed.
System Interruption
In case of power failure, readjust the current time and regeneration start time according to the manual after the
power supply is restored. (Refer to page 18 for setting time.)
When the water supply in a residential area is shut down, your main water valve should be closed immediately. The
municipal water supply may cause negative pressure on the household pipeline and damage the equipment. When
the water supply is shut down, the bypass valve of the water softener should be placed in "Bypass Position." When
the water supply is restored, the faucet in the home should be opened first to release the contaminated water. The
bypass valve should then be moved to "Service Position" after water is clear, otherwise, pollutants in the water pipe
may enter the water softener and damage the machine, leading to valve or resin failure.