Setting The Regeneration Type
IMPORTANT!
!
The system offers three mode types depending on your needs. It is recommend to set the system
at (tM) Time Meter mode which allows the system to regenerate at 2 am in the morning once the
gallons reaches zero.
Choose Between Time, Meter or Meter Delayed.
/t M
TIME METER DELAYED
Regenerate at 2 am on the night
after the set gallon reaches zero.
A: Press the SETTINGS button to adjust
the regeneration type setting.
B: Press UP or DOWN buttons to
change mode.
Press the SETTINGS button to accept
and continue.
/ t
TIMER
Allow system to regenerate based
on set time interval.
www.proaquawater.com
Valve Programing
NOTE:
*
It is recommended to set the system to
Time Meter Delayed.
/M
METER
Regenerate immediately after the
set gallon reaches zero.
11:30
SEt - 2 tYPE
FLASHING
11:30
tYpE-
tM
FLASHING