Parameter No.
P1
Maximum frequency
P9
Electronic thermal O/L relay
P19
Base frequency voltage
P22
Stall prevention operation level
P57
Restart casting time
Number
P67
occurrence
P68
Retry waiting time
Reset selection/ disconnected PU
P75
detection/ PU stop selection
P77
Parameter write selection
P78
Reverse rotation prevention selection
P79
Operation mode selection
P80
Motor capacity
PU communication check interval
P122
time
P160
Extended function selection
Frequency setting/key lock operation
P161
selection
P180
RL terminal function selection
Mitsubishi FR-D720 series parameter settings Note
※ doing all parameter clear the ALLC] to 1. Parameter settings before
※ 2.Pr77 to be set after the parameter settings of the other all over
※ that the settings after the 3.Pr77, to perform and hold the key lock the
[MODE] button
Table. 9 Parameter setting: Mitsubishi FR-D720 series
Parameter
of
retries
at
PRC-003A
PRC-006A
3.6
58.5
alarm
0.75
36
YO99-0874-DI-002-18
PRC-012A
60
9.3
15.1
200
75.5
80.1
0
10
6
1
1
1
3
2.2
3.7
9999
0
10
62
PRC-018A
21.0
72.3
5.5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prc-006aPrc-012aPrc-018a

Table of Contents