INSTALLATION
TECHNICAL INFORMATION FOR THE INSTALLER
In order to install the cooker top into the kitchen fixture, a hole with the dimensions shown
in fig. 1.1a or 1.1b has to be made, bearing in mind the following:
30cm wide models:
A 40mm ventilation gap must be provided between the bottom of the appliance
and any cabinetry, draw unit or appliance.
If the base of the cooktop is accessible through a cupboard or drawer space after
installation, a thermal protection barrier is not required.
If the cooktop is installed above an oven, the two appliances shall be connected
to the gas and/or electrical supply with independent connections.
60cm wide models:
A 40mm ventilation gap must be provided between the bottom of the appliance
and any cabinetry, draw unit, thermal protection barrier or appliance.
If the cooktop is installed directly above an oven (which does not have a cooling
fan motor) a thermal protection barrier must be installed below the base of the
cooktop as indicated in fig. 1.1d.
If the base of the cooktop is accessible through a cupboard or drawer space after
installation or if the oven installed below the cooktop has a cooling fan motor, the
thermal protection barrier is not required.
If the cooktop is installed above an oven, the two appliances shall be connected
to the gas and/or electrical supply with independent connections.
75cm wide models:
A 40mm ventilation gap must be provided between the bottom of the appliance
and any cabinetry, draw unit, thermal protection barrier or appliance.
If the cooktop is installed directly above an oven (which does not have a cooling
fan motor) or if its base is accessible through a cupboard or drawer space after
installation, a thermal protection barrier must be installed below the base of the
cooktop as indicated in fig. 1.1d.
If the oven installed below the cooktop has a cooling fan motor, the thermal
protection barrier is not required.
If the cooktop is installed above an oven, the two appliances shall be connected
to the gas and/or electrical supply with independent connections.
90cm wide models:
A 40mm ventilation gap must be provided between the bottom of the appliance
and any cabinetry, draw unit, thermal protection barrier.
If the base of the cooktop is accessible through a cupboard or drawer space after
installation, a thermal protection barrier must be installed below the base of the
cooktop as indicated in fig. 1.1d.
All models:
The cooker top must be kept no less than 200 mm away from any side wall (from
side edge of cutout - figs. 1.1a, 1.1b, 1.1c).
The hob must be installed at least 60 mm from the wall (from rear edge of cutout
- fig. 1.1a, 1.1b).
There must be a distance of at least 650 mm between the hob and any wall
cupboard or extractor hood positioned immediately above (see fig. 1.1c).