Description
30cm wide models
60cm wide models
75cm wide models
90cm wide models
(*)
For models with metal trim/s add 4mm to the measurement for each trim.
Example: front metal trim= B+4mm.

(**)
from the top of countertop to bottom of cooktop.

flush installation.
(***)
200mm
Fig. 1.1c
A (*)
B (*)
C (**)
300
520
50 ( 1 )
54 ( 2 )
600
510
or 60 ( 2 ) for
750
510
flush
installation
900
510
X
Cooktop
installed
Measures (mm)
D
D1 (***)
270
305
560
605
480
560
755
840
905
1
(
) X=8 mm
2
(
) X=4 mm
The thermal protection barrier must
be:
removable with the use of a
tool for installation and service;
heat-resistant;
made
conductivity material.
Clearance
Space for
connections
E
E1 (***)
E1A (***)
525
21
515
10
515
10
515
10
from
low
thermal
Thermal
protection
barrier
Door
Fig. 1.1d
E1B (***)
24
25
25
25
11
11