SETTING THE MINIMUM OF THE
COOKTOP BURNERS
In the minimum position the flame must
have a length of about 4 mm and must
remain lit even with a quick turn from the
maximum position to that of minimum.
The flame adjustment is done in the
following way:
Turn on the burner.
Turn the tap to the 'MINIMUM' position.
Take off the knob.
With a small flat screwdriver turn the
screw "A" to the correct regulation (fig.
2.3).
Models with dual burner: For the dual
burner set the minimum (as indicated
above) for both the gas valves (one for
the inner and one for the outer crown).
The operations must be carried out
one gas valve at a time.
Normally for LPG tighten up the
regulation screw.