SECTION OF THE SUPPLY CABLE
TYPE "H05V2V2-F"
resistant to temperatures of 90°C
220-240 V
50-60 Hz
or
220V ac 18/3 (*) (**)

(*)
Connection possible with plug and outlet

(**)
Connection with wall box connection.
REPLACING THER POWER SUPPLY CABLE
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
To connect the supply cable:
Unhook the terminal board cover by inserting a screwdriver into the two hooks "A"
(fig. 3.1).
Open the cable gland by unscrewing
screw "F" (fig. 3.2), unscrew the terminal
screws and remove the cable.
The new supply cable, of suitable type
and section, must be connected to the
terminal board following the diagram in
fig. 3.3.
Close and hook again the terminal
board cover.
NOTE: The earth conductor must be left
about 3 cm longer than the others.
F
22
22
3 x 0,75 mm
2
(*) (**)
A
Fig. 3.2
L
1
E
N (L
)
2
Fig. 3.1
Fig. 3.3