18 Messages
► As soon as Measurement enable appears in the
status bar, the measurement can be started.
– The chimney sweep function remains active for a
period of 40 minutes. Before this period expires, a
message allowing extension of the period by 30
minutes is displayed.
– To abort the function prematurely, switch to a dif-
ferent boiler operating mode.
17.2 Emission measurement for external
boilers
If necessary, use the menu output test heating circuit
> 14
to carry out the emission measurement on an
external boiler. In this menu, the electrical outputs for
the remote boiler, 3-way motor valve as well as for
the heating circuit pump and heating circuit mixing
valve can be switched on/off manually.
44
18 Messages
Messages that arise are shown in the eco
touch
control display, each message is saved in the
message log
>
16.
Handling of messages
Button 1: Close window, change to main screen. The
message remains active, i.e. the burner may not start
depending on the type of message.
Button 2: Switch to the message log
Button 3: Acknowledge the message.
For some messages, an acknowledgement is only
possible if the cause of the fault has been rectified;
the burner may then restart after a heating request is
received.
Alarm symbol
This symbol indicates an alarm message: The
boiler is no longer ready for operation if such a mes-
sage occurs.
Note symbol
This symbol indicates a notification message:
The boiler is still ready for operation.
Operation manual ecotop-zero, ecotop-light
manager-
> 16