Mod bus TCP
With this function, the eco
to communicate with a LOXONE control, e.g. for
smart home controls, in both directions.
i
Installation and configuration of this function
must be performed by the customer, i.e. they
are not included in the commissioning and ser-
vice activities for your SOLARFOCUS system.
Requirements for use
– ecomanager-touch control with 7" display
– Software version of boiler control: from V 19.050
nator
or with thermi
II touch from V 19.072
– Master and display must be in the same network.
Modbus TCP interface
– The connection is made via port 502
– The UnitIdentifier (UnitID) for the connection to
the slave is 1.
– To establish a connection with the panel, all that
needs to be known is the IP address of the con-
trol. The connection can be established via the
master.
– The instructions can be found here:
Setting in the boiler control
– Activate the Mocbus TCP interface
– The green colour
1
denotes the availability of the
interface and the active data exchange. Red
the display on the other hand indicates an inter-
ruption in the connection or a missing activation.
Operation manual ecotop-zero, ecotop-light
manager-touch
control is able
2
mySOLARFOCUS app
Pressing the button displays the screen with inform-
ation relating to online registration for the
mySOLARFOCUS app (serial number, PIN, status,
etc.)
Detailed information on use of mySOLARFOCUS
app
> 35
Language selection
The language of the operating unit can be set on this
screen.
i
If a text is not available in the selected lan-
guage, it will be displayed in English.
Date and time
in
Summer/winter time is changed automatically when
the Switchover Summer-Winter parameter has the
value Europe. Switchover takes place on the last
Sunday of the months of March and October. If Amer-
ica is set, the clock is changed to summer time on the
first Sunday in April.