Reduced mode
The heating circuit pump is activated. A
shutdown occurs whenever
– the ambient switch off temperature
for reduced mode is reached or
– a room temperature sensor is used and where
nominal room temperature for reduced mode has
been reached.
The heating circuit is provided with the reduced tem-
perature, i.e. calculated required flow temperature
minus reduction.
Time switch
In this operating mode, the timed switch-
over between Heating mode and
Reduced mode is defined. The times for
heating mode can be entered per day or
by block.
Usage example: Heating mode should be active dur-
ing the day. At night, it should be changed to reduced
mode.
Switch off heating circuit
Heating circuit pump and heating circuit
mixers are switched off. The anti-freeze
function for the heating circuit is enabled
(i.e. the heating circuit pump is switched
on whenever the outside temperature drops below
the anti-freeze temperature).
Operation manual ecotop-zero, ecotop-light
Holiday mode
Holiday mode deactivates the active
operating mode for the entered duration.
activates the frost protection mode for the
heating circuit for the duration of the hol-
iday.
activates the reduced mode for the heating
circuit for the duration of the holiday.
This icon indicates activated holiday mode
in the Heating circuit screen.