Limitation of liability To ensure reliable and efficient operation of your boiler, the following points are extremely important: SOLARFOCUS GmbH. accepts no liability for injury or material damage resulting from: Professional installation of the heating boiler. – Failure to observe the instructions in this manual.
A should preferably be used. This delivers savings potential of up to 80 % in drive energy (compared to conventional heating pumps) with identical feed results. Operation manual therminator II touch...
If the boiler temperature falls below the set Heat dis- consequential damage to the heating system. The sipation maximum boiler temperature minus 1°C valve is closed during normal operation. again, the pumps and mixers will be operated in stan- dard mode again. Operation manual therminator II touch...
7 Heat exchanger with interior turbulators 8 Stainless steel hopper with stainless steel com- bustion grate 9 Combustion chamber door 10 Combustion chamber 11 Ignition device (optional), exterior on the left side of the boiler Operation manual therminator II touch...
The hot combustion air flows through the heat exchan- and leaves the boiler through the flue pipe into the chimney. The speed-controlled ID fan on the rear of the boler sucks the air through the boiler. Operation manual therminator II touch...
[3] A draught stabiliser must be fitted if the specified draught is exceeded [4] Flue gas temperature can be adjusted electronically Flue gas values in mg/m 3 are baed on 13% O 2 of the volume flow Operation manual therminator II touch...
7 Boiler output test: CAUTION, only to be under- taken by qualified personnel. 8 Qualified personnel menu > 14 [1] The button is only visible if qualified personnel are log- ged in. [2] Button is only visible if a message is active. Operation manual therminator II touch...
Password reset The current password is reset to the value solarfocus. Accept as new password Enter a new password in the input field and press the button.
(i.e. not included in the commissioning and service activities). The following points are helpful for setting up a PC/- router to control the VNC server, which requires know- ledge of networking technology. Operation manual therminator II touch...
Page 15
VNC Viewer on the local PC. Press the Reset password button to reset the pass- word to the default password solarfocus. Version 2: Installation of VNC viewer for access from an external PC (PC outside the home net- work) Fig.
Page 16
To and CC or manually entered in the recipient line. Pressing the button displays the screen with infor- mation relating to online registration for the mySOLARFOCUS app (serial number, PIN, status, etc.) > Fig. 2-43, page 31 Operation manual therminator II touch...
Fuel to be used Dry, easily combustible small piece of material (e.g. small chopped logs, wood shavings, bush wood chips). Split logs, medium-sized, dry (recommended: 0.5 m lang). Split logs, large, dry (recommended: 0.5 m long). Operation manual therminator II touch...
– the flue gas temperature falls below the Exhaust cutoff temperature. – the residual oxygen content in the flue gas exceeds a predefined value for a long period of time. Ä Message on the status line: Burn-off logs finis- hed. Operation manual therminator II touch...
► Wait for a moment until the rest of the material is will be asked whether you would like to start burn- visibly burning. off with or without glow holding. ► As described above, add more log wood and close the filling chamber door. Fig. 2-22_01-100 Operation manual therminator II touch...
► After filling the boiler, close the filling chamber of different fuel; see detailed description > 17 door. ► In the boiler control, select the Automatic log wood function operating mode and press the Start button. Operation manual therminator II touch...
Example of use for the In blocks release type: daily heating mode, the boiler is filled with log wood in the evening and the burner is to start every day at 06:00 (if there is a heating request). Operation manual therminator II touch...
The delay set here is used to determined an average value for the outdoor temperature (= Average outdoor temperature). The heating circuit pump switches on if the Average temperature and the Current outdoor temperature fall below the cutoff temperature (within the heating Operation manual therminator II touch...
Page 24
Depending on the standard of building and insulation, it is advisable to change over from the 2-point to a 3- point heating curve. In contrast to the 2-point heating curve, it is possible to stipulate a third temperature 11, Operation manual therminator II touch...
Required tem- buffer is reserved for supplying the DHW tank/fresh perature 1 is reached. A new charge starts when the water module. DHW tank temperature falls to the value Required tem- perature 1 less Hysteresis. Operation manual therminator II touch...
Automatic. The fresh water module regulates the (DHW area) of the buffer tank. temperature at which the connected hot water devices receive water. Operation manual therminator II touch...
10.2.2 Temperature- and time-controlled recir- culation Temperature-controlled recirculation is only available if a temperature sensor is connected for the recirculation Fig. 2-36_07-003 temperature. The control takes the recirculation temperature (required recirculation temperature) into Operation manual therminator II touch...
In order to ensure optimum and efficient use of - No time release has been set. the buffer tank, the difference between these As soon as DHW is drawn, the recirculation pump is two temperatures should be > 15°C. triggered. Operation manual therminator II touch...
The solar yield is displayed in the mySOLARFOCUS app > 30 (prerequisite: A solar system controlled by the manager- touch controleco , including thermal unit counter). Operation manual therminator II touch...
IP configuration Fig. 2-41_01-126-05 ► Continue by pressing Accept ► To access the IP-VNC icon, select it in the control – Selection menu screen – Customer menu screen – Trained qualified personnel button Fig. 2-42_01_127 Operation manual therminator II touch...
► Enter the data for your heating system (serial num- ber and PIN). The weather forecast data for the weatherman function are sent to the boiler control on the basis of the Postcode and Location fields. Operation manual therminator II touch...
Monday - Sunday and In blocks are not availa- ble for DHW tank mode. 14.7 Approve additional users You can enable access to your control for additional users, for example heating engineers. Issuing approval. ► Select the Approval menu item. Fig. 2-47_15_005 Operation manual therminator II touch...
II touch. – Registration of the heating boiler on the web server Fig. 2-50_01_121 SOLARFOCUS, or in the mySOLARFOCUS app, > Weatherman function Off: The weather forecast is shown in the display, but After successful online registration of the heating sys- does not influence the control at all.
Within the heating period, the inside setpoint tem- perature is reduced as a maximum to the inside set- point temperature reduced mode set in the heating circuit room settings screen. Operation manual therminator II touch...
► Open the cladding door and combustion chamber door. ► Place the ash pans in front of the combustion chamber. ► Clear the ash present in the combustion chamber using the ash scraper in the ash pan. Operation manual therminator II touch...
Page 36
Visual inspection of the combustion grate The stainless steel combustion grate is a wearing part and must be regularly checked for wear. In the event of advanced wear (visual check), replace the stainless steel combustion grate. Operation manual therminator II touch...
17 Perform emissions mea- By purchasing a boiler maintenance agreement, surement SOLARFOCUS will manage the annual appointment and contact you directly when a maintenance appoint- The emissions measurement at the boiler is a legal ment is due. Information on the maintenance agree-...
In this menu, the electrical outputs for the remote boiler, 3-way motor valve as well as for the heating circuit pump and heating circuit can be swit- ched on/off manually. Fig. 2-57_01-102 Operation manual therminator II touch...
Page 39
Feeding too much fuel (log wood), the boiler Insufficient boiler cleaning could provide too little energy. – see chapter on Maintenance and cleaning > 35 – Check the buffer cylinder temperature before refil- ling; only supply as much fuel as required. Operation manual therminator II touch...
Package can be purchased at any time for one-off ser- occurred. The boiler is operationally ready again. vicing work on commissioning by SOLARFOCUS plant customer service or by a certified specialist ser- Insufficient boiler cleaning vice partner.
Page 41
The commissioning form signed by the custo- mer is a prerequisite. A copy of the commissioning Checklist (for all maintenance packages) form must be transferred to SOLARFOCUS within 10 days of commissioning. The warranty starts upon the The annual boiler service includes the following: date of commissioning.
Page 42
The repair and/or warranty replacement shall be Wilful damage. carried out on site or in the SOLARFOCUS factory Incorrect operation and failure to perform main- at our discretion. tenance and cleaning as prescribed. The company SOLARFOCUS will determine whe- Damage due to force majeure (water, fire, etc.).
The relevant, country-spe- installation and main- cific standards and guidelines must be observed for the installation and operation of the tenance solid fuel boiler. Operation manual therminator II touch...
Page 44
makes you independent Innovative products to spare the environment and your wallet! Everything from one supplier Biomass heating - Solar systems - Heat pumps - Fresh water equipment Tested state-of-the-art technology – EN ISO 9001 certified Austria...