5.4.6 Operating hours counter
The operating hours of the individual outputs are lis-
ted in this menu. These are only counted when the
corresponding output is switched on.
The display of the pellet consumption is accessed by
clicking on the button 1. Pressing the Reset button
sets the pellet consumption back to 0 and in the bot-
tom area
4
the consumption is displayed over the
elapsed time.
The heat distribution is reached via 2. Displayed here
are the operating hours during which heat was
requested by the various connected devices.
Operation manual ecotop-zero, ecotop-light
The integrated heat quantity measurement is
reached via 5. The pellet consumption is displayed
with maximum 15% deviation and is used together
with the efficiency factor for calculating the heat
quantity. The efficiency factor depends on the dif-
ference between the ambient temperature and flue
gas temperature, residual oxygen content and energy
content of the pellet 6.
There is no need for an additional heat quantity
counter.
The corresponding manufacturer declaration is
present and can be accessed here: