6.2

Disassembly and disposal

To be able to dismount the panel PC from the mounting arm, you must first have disconnected the power
supply and the cables (see Chapter 6.1 Disconnecting the power supply and cables [} 42]).
Disassembly mounting arm tube
Damage to property due to falling down
If the panel PC is suspended from the ceiling and you undo the cap nut of the mounting arm adapter
without securing it, the panel PC will fall down.
• Make sure the panel PC is secured against falling down before you undo the slotted nut of the mounting
arm adapter.
To remove the panel PC from the mounting arm tube, follow the steps below, shown in Figure 35:
1. Loosen the slotted nut of the mounting arm adapter with a hook wrench size 58-62 (C9900-Z263) in
counterclockwise direction (section A).
2. Unscrew the hexagon socket screw (1) a few turns with a 3 mm Allen key (section B).
3. Pull the mounting arm tube out of the mounting arm adapter (section C).
4. Pull the connecting cables out of the mounting arm tube.
5. Screw in the hexagon socket screw until it no longer protrudes on the outside.
ð You have removed the mounting arm tube from the mounting arm adapter.
A
Fig. 35: Disassembly mounting arm tube
Disassembly toolboard and handle
To remove the handle from the device, loosen the two M5 screws on the bottom of the device (see Fig. 36).
Make sure that the handle is secured against falling.
CP37xx-1600
NOTICE
B
1
Version: 1.9
Decommissioning
C
43