  • Page 3: Table Of Contents

    Table of contents Table of contents 1 Notes on the documentation........................ 5 2 For your safety ............................ 6 Description of safety symbols ...................... 6 Intended use .............................  6 Fundamental safety instructions .......................  7 Operator's obligation to exercise diligence.................. 7 Notes on information security...................... 8 3 Product overview ............................
  • Page 4 Table of contents Version: 1.5 CP32xx-2xxx-0020...
  • Page 5: Notes On The Documentation

    Copyright © Beckhoff Automation GmbH & Co. KG. Publication of this document on websites other than ours is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.
  • Page 6: For Your Safety

    Exclusion of liability Beckhoff shall not be liable in the event of non-compliance with this documentation and thus the use of the devices outside the documented operating conditions.
  • Page 7: Fundamental Safety Instructions

    For your safety Fundamental safety instructions The following safety instructions must be observed when handling the device. Application conditions • Do not use the device under extreme environmental conditions. • Never use the device in hazardous areas. • Do not carry out any work on the device while it is live. Always switch off the supply voltage for the device before mounting it, replacing device components, or rectifying malfunctions.
  • Page 8: Notes On Information Security

    For your safety Notes on information security The products of Beckhoff Automation GmbH & Co. KG (Beckhoff), insofar as they can be accessed online, are equipped with security functions that support the secure operation of plants, systems, machines and networks. Despite the security functions, the creation, implementation and constant updating of a holistic security concept for the operation are necessary to protect the respective plant, system, machine and networks against cyber threats.
  • Page 9: Product Overview

    Product overview Product overview With the CP32xx series, you can use multitouch as a high-end Panel PC directly in the field. The devices in the robust aluminum housing are designed for mounting arm installation. The connection cables are routed through the mounting arm. Thanks to its processors, you can use the Panel PC for the following applications, among others: •...
  • Page 10: Structure

    Product overview Structure Figure 1 shows the structure of the device as an example for all CP32xx variants. Fig. 1: CP32xx_structure Table 1: Key: CP32xx structure Component Description Example: Mounting arm C9900-M802 Mounting arm for mounting on ceiling Touch Screen Operation of the Panel PC Heat sink Access to the motherboard Mounting arm adapter...
  • Page 11: Interface Description

    Product overview Interface description The panel PC has the following interfaces: • Power supply (XD01) • Ethernet (XF01, XF02) • USB (XG01-XG04) The interfaces are located at the bottom of the back of the housing. The push-pull built-in power socket for the power supply as well as one of the two push-pull built-in Ethernet sockets are freely accessible.
  • Page 12: Ethernet Rj45

    Product overview 3.2.2 Ethernet RJ45 The CP32xx has two Ethernet RJ45 interfaces (XF01, XF02) in the form of push-pull built-in Ethernet sockets. The 100Base-T and 1000Base-T Ethernet standards enable the connection of corresponding network components and data rates of 100/1000 Mbit/s. The required speed is selected automatically. There is a connection cable inside the column unit of the mounting arm.
  • Page 13: Usb

    Product overview 3.2.3 In the High Performance Class, the CP32xx has two USB 3.0 interfaces and two USB 2.0 interfaces. In the Smart Performance Class, the panel PC has one USB 3.0 interface and two USB 2.0 interfaces. The assignment of the interfaces varies depending on the device generation. The following table provides information about the assignment of the interfaces.
  • Page 14: Name Plate

    Product overview Name plate The name plate provides information on the equipment fitted to the Panel PC. The name plate shown here serves only as an example. xxxxxxxx xxxxxxxxxxxxx xxxxxxxxxxxxx xxxxxxxxxxxxx Fig. 6: CP32xx_nameplate Table 6: Key: nameplate CP32xx Description Model: The last four digits indicate the device generation Serial number (BTN) Date of manufacture Mainboard...
  • Page 15: Connecting Cable

    Connecting cable Pre-assembled connection cables for connecting the power supply and pre-assembled Ethernet connection cables are optionally available. You can order them from Beckhoff Customer Service by specifying the following article descriptions (see Chapter 9.1 Service and Support [} 45]). Table 7: Power supply connection cable...
  • Page 16: Commissioning

    If you, as the user, require additional protection for the touch screen against dirt and scratching, for example due to dirty hands, this can be achieved with a Beckhoff protective film. The film provides short-term protection for a few days.
  • Page 17: Transport And Storage

    5. Check the contents for visible shipping damage. 6. In case of discrepancies between the package contents and the order, or in case of transport damage, please inform Beckhoff Service (see Chapter 9.1 Service and Support [} 45]). CP32xx-2xxx-0020 Version: 1.5...
  • Page 18: Mounting

    Commissioning Mounting The CP32xx Panel PC is designed for mounting on the mounting arm. The environmental conditions specified for operation must be observed (see chapter 8 Technical data [} 44]). To align the device according to your requirements, four different mounting arms are available on which you can mount the device.
  • Page 19: Fig. 8 Cp32Xx_Mounting Arm Adapters

    Push button extension You have the option to order the additional C9900-M800 push button extension from your Beckhoff distributor. For explanations of the push button extension, functions and mounting, refer to the associated C9900-M800 manual.
  • Page 20: Dimensions

    Commissioning 4.2.1 Dimensions The dimensions of the Panel PC are for aligning the device on the mounting arm. All dimensions are in mm. Fig. 10 illustrates the dimensions of the 18.5-inch Panel PC. 457,93 Fig. 10: CP32xx_dimensions 18.5-inch Fig. 11 illustrates the dimensions of the 24-inch Panel PC. 577,73 Fig. 11: CP32xx_dimensions 24-inch Version: 1.5...
  • Page 21: Mounting Arm Installation

    Commissioning 4.2.2 Mounting arm installation NOTE Extreme environmental conditions Extreme environmental conditions can cause damage to the device. • Avoid extreme environmental conditions. • Protect the device from moisture and heat. Observe the following points when mounting the panel PC on the mounting arm: •...
  • Page 22: Fig. 13: Cp32Xx_Mounting On Mounting Arm, Variant 2

    Commissioning Fig. 13: CP32xx_mounting on mounting arm, variant 2 If you have chosen the rotary adapter with lever in order to be able to rotate the device on the mounting arm, the installation is done in the same way as with the standard mounting arm adapter. Version: 1.5 CP32xx-2xxx-0020...
  • Page 23: Mounting The Keyboard Shelf

    Mounting the keyboard shelf You can mount a shelf for the keyboard and mouse below the PC. You can obtain the shelf from your Beckhoff distributor under the order identifier C9900-M801. You have three options for mounting the shelf (see Figure 14): •...
  • Page 24: Mounting The Adapter Housing

    Commissioning 4.2.4 Mounting the adapter housing You have the possibility to mount the C9900-M808 adapter housing for a Euchner EKS RFID reader on the Panel PC. The shipment includes only the empty housing, without the Euchner EKS RFID reader. There are two drill holes on the back of the Panel PC on the right for mounting the adapter housing. The housing is located to the left of the PC after installation.
  • Page 25: Mounting Of Extensions

    Commissioning 4.2.5 Mounting of extensions You have the option to mount additional extensions at the Panel PC. These are the bracket for a signal lamp (C9900-M811) and the holder for an RFID card (C9900-M812). Signal lamp bracket You can mount a bracket for a signal lamp (C9900-M811) with an M12 connection socket on devices with mounting arms C9900-M803 and C9900-M804.
  • Page 26: Fig. 19 Cp32Xx_Adhesive Strip Rfid Card

    Commissioning 4. Press the holder with the adhesive strips (see Fig. 19) onto the front foil. Fig. 19: CP32xx_adhesive strip RFID card ð You have mounted the bracket. Version: 1.5 CP32xx-2xxx-0020...
  • Page 27: Connecting The Panel Pc

    Commissioning Connecting the Panel PC CAUTION Risk of electric shock Dangerous touch voltages can lead to electric shock. To avoid electric shock, adhere to the following points: • Never connect or disconnect the device cables during a thunderstorm. • Provide protective earthing for handling the device. To make the panel PC ready for operation, you have to connect it.
  • Page 28: Fig. 20 Cp32Xx_Position Functional Earth Cable

    Commissioning Fig. 20: CP32xx_Position functional earth cable The extensions shown are the following: • 1: Option C9900-M802 mounting arm for mounting on ceiling • 2: Option C9900-M803 stand for mounting on the control cabinet • 3: Option C9900-M804 stand for mounting on hall floors •...
  • Page 29: Connecting Cables And Power Supply

    Commissioning 4.3.2 Connecting cables and power supply NOTE Incorrect connection procedure Incorrect procedure when connecting the cables and the power supply can cause hardware damage. • Follow the documented procedure for connecting the cables and the power supply. • Always connect the cables first and only then switch on the power supply. •...
  • Page 30 Commissioning Connecting the power supply Cables with the following maximum cable cross-sections must be used to connect the power supply: • 2.5 mm if using the panel PC without a mounting arm • 2.5 mm if using the panel PC on the C9900-M802 und C900-M805 mounting arms; the plug is provided •...
  • Page 31: Switching The Panel Pc On And Off

    Commissioning Switching the Panel PC on and off First switching on and driver installation NOTE Public networks Connecting the PC to public networks without additional protective measures can compromise the safety of the device. • Protect the PC before connecting it to public networks. The panel PC has a mains switch that switches 24 V.
  • Page 32: Decommissioning

    Decommissioning Decommissioning NOTE Hardware damage due to power supply A connected power supply can cause damage to the Panel PC during disassembly. • Disconnect the power supply from the device before starting to disassemble it. As part of the decommissioning of the Panel PC, you must first disconnect the power supply and cables. Afterwards, you can dismount the device from the mounting arm.
  • Page 33: Disassembly And Disposal

    Decommissioning Disassembly and disposal To be able to dismount the panel PC from the mounting arm, you must first have disconnected the power supply and the cables (see Chapter 5.1 Disconnecting the power supply and cables [} 32]). Dismounting from the mounting arm Depending on the selected mounting arm on which you mounted the device, the procedure for dismounting is different.
  • Page 34: Fig. 23: Cp32Xx_Dismounting From Mounting Arm, Variant 2

    Decommissioning Fig. 23: CP32xx_dismounting from mounting arm, variant 2 Dismounting the keyboard shelf To dismount the keyboard shelf, depending on the mounting option selected, you must either remove the Torx TX25 screws from the holes on the bottom of the PC or the push button extension, or remove the TX25 screws from the mounting plate.
  • Page 35: Maintenance

    Maintenance Maintenance CAUTION Risk of electric shock Working on the panel PC when live can lead to electric shock. • Switch off the power supply before cleaning the device or replacing device components. Excluded from this is the replacement of hard disks and SSDs in RAID configuration and fan cartridges. Maintenance measures increase the efficiency of the device by ensuring long-term functionality.
  • Page 36: Table 10 Replacement Recommendations For Pc Components

    NOTE Use of incorrect spare parts The use of spare parts not ordered from Beckhoff Service can result in unsafe and incorrect operation. • Only use spare parts that you have ordered from Beckhoff Service. Beckhoff Panel PCs are manufactured from components of the highest quality and robustness. They are selected and tested for best interoperability, long-term availability and reliable function under the specified environmental conditions.
  • Page 37 Maintenance • Wrist grounding strap, especially for sedentary activities; • grounded and electrostatically dissipating equipment and operating materials (e.g. tools) within the ESD protection zone. If it is not possible to create an ESD protection zone, you can still protect the device against ESD damage. The following measures serve this purpose, for example: •...
  • Page 38: Access To Device Components

    Maintenance 6.2.1 Access to device components In order to be able to exchange the storage media, the battery or the fan, you must first gain access to these device components. Access to storage media Access is gained to the storage media from the back of the panel PC. The storage media are located behind the lateral cover flap.
  • Page 39: Fig. 26 Cp32Xx_Battery And Fans

    Maintenance Fig. 26: CP32xx_battery and fans CP32xx-2xxx-0020 Version: 1.5...
  • Page 40: Replacing The Storage Media

    If you want to exchange a storage medium according to Beckhoff's recommendation, you must copy the data from the old to the new storage medium. You can use the Beckhoff Service Tool (BST) for this purpose. BST is a graphical backup and restore program for PCs with a Windows operating system. You can create an image of your operating system and use it to back up the operating system.
  • Page 41: Replacing The Battery

    NOTE Incorrect battery type Inserting the wrong type of battery can damage the device. • Only replace the battery with a replacement battery from Beckhoff Service. • When replacing the battery, make sure that the polarity is correct. NOTE Battery damage Incorrect handling of the motherboard battery can damage it.
  • Page 42: Replacing The Fan

    The industrial PC may be damaged if the wrong type of fan is installed. • Only replace the fan with a replacement fan from Beckhoff Service. The fans ensure optimal cooling of the panel PC. Order replacement fans exclusively from Beckhoff Service (see Chapter 9.1 Service and support).
  • Page 43: Troubleshooting

    No power supply to the panel PC Check the power supply cable Cable not connected 1. Correctly connect the cable 2. Call Beckhoff Service Panel PC boots, software starts, The cause of the error is the Call the machine or software...
  • Page 44: Technical Data

    Technical data Technical data Table 13: Technical data Product designation CP32xx-2xxx-0020 Dimensions (W x H x D) CP3218: 458 x 352 x 89 mm CP3224: 578 x 415 x 89 mm Weight CP3218: approx. 8.5 kg CP3224: approx. 10 kg Supply voltage 20.4-30 V (24 V power supply unit, NEC class 2)
  • Page 45: Appendix

    Telephone: + 49 (0) 5246/963-0 Fax: + 49 (0) 5246/963-198 E-mail: info@beckhoff.de The addresses of the worldwide Beckhoff branches and agencies can be found on our website at http:// www.beckhoff.com/. You will also find further documentation for Beckhoff components there.
  • Page 46: Approvals

    Appendix Approvals The Panel PC has the following approvals: • CE • EAC • UKCA • FCC You will find all other applicable approvals on the nameplate of your device. FCC approvals for the United States of America FCC: Federal Communications Commission Radio Frequency Interference Statement This device was tested and complies with the limits for a digital device of class A, according part 15 of the FCC regulations.
  • Page 47 List of figures List of figures Fig. 1 CP32xx_structure......................... Fig. 2 CP32xx_access to interfaces....................... Fig. 3 CP32xx_voltage socket pin numbering..................Fig. 4 CP32xx_Ethernet interface pin numbering .................. Fig. 5 CP32xx_USB interface pin numbering..................Fig. 6 CP32xx_nameplate........................Fig. 7 CP32xx_mounting arms....................... Fig.
  • Page 48 List of tables List of tables Table 1 Key: CP32xx structure ......................... Table 2 Voltage socket pin assignment ....................Table 3 Ethernet interface pin assignment....................Table 4 Assignment USB interfaces ......................Table 5 USB interface pin assignment...................... Table 6 Key: nameplate CP32xx....................... Table 7 Power supply connection cable....................