  • Page 1 Manual | EN CP77xx Panel PC 2024-03-21 | Version: 3.4...
  • Page 3: Table Of Contents

    Mounting ............................ 19 Connecting the panel PC ........................  19 4.3.1 Grounding the panel PC.................... 21 4.3.2 Connecting cables and power supply ................ 22 5 Beckhoff Device Manager ........................ 23 6 Decommissioning ...........................  25 7 Maintenance ............................ 26 Cleaning ............................ 26 Maintenance............................  28 7.2.1 Replacing the battery .......................
  • Page 4 Table of contents Version: 3.4 CP77xx...
  • Page 5: Notes On The Documentation

    EP1590927, EP1789857, EP1456722, EP2137893, DE102015105702 and similar applications and registrations in several other countries. ® EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany Copyright © Beckhoff Automation GmbH & Co. KG, Germany. The distribution and reproduction of this document as well as the use and communication of its contents without express authorization are prohibited.
  • Page 6: For Your Safety

    Exclusion of liability Beckhoff shall not be liable in the event of non-compliance with this documentation and thus the use of the devices outside the documented operating conditions.
  • Page 7: Fundamental Safety Instructions

    For your safety Fundamental safety instructions The following safety instructions must be observed when handling the device. Application conditions • Do not use the device under extreme environmental conditions. • Only use the device in hazardous areas if it is explicitly designed for this purpose. •...
  • Page 8: Notes On Information Security

    For your safety Notes on information security The products of Beckhoff Automation GmbH & Co. KG (Beckhoff), insofar as they can be accessed online, are equipped with security functions that support the secure operation of plants, systems, machines and networks. Despite the security functions, the creation, implementation and constant updating of a holistic security concept for the operation are necessary to protect the respective plant, system, machine and networks against cyber threats.
  • Page 9: Product Overview

    Product overview Product overview The CP77xx Panel PC series is designed for installation on the mounting arm and represents a powerful platform for use in machine and system engineering. Thanks to its processors, you can use the panel PC for the following applications, among others: •...
  • Page 10: Structure

    Product overview Structure Fig. 1: Structure Table 1: Legend CP77xx structure Component Description 4 threaded holes M6 x 18 mm For installation on the wall Name plate Information on the equipment of the panel PC Connection section Access to interfaces Cover Access to battery and storage media Display and touch screen glass Operation of the panel PC Version: 3.4...
  • Page 11: Interface Description

    Product overview Interface description In the basic configuration, the panel PC includes the following interfaces: • RS232 (X100) • Power supply (X101) • Ethernet RJ45 (X102, X103) The interfaces are located at the rear of the panel PC (see fig. 2). A 19-inch device is shown as an example, with the interfaces located at the bottom right at the rear.
  • Page 12: Rs232

    Product overview 3.2.1 RS232 The COM1 serial interface (X100) is fed out via a 12-pin round connector. The signals comply with the RS232 standard. The interface is used to connect serial peripheral devices. The C9900-K234 adapter cable is supplied with the panel PC. This allows you to connect serial peripheral devices with standard D-sub connector.
  • Page 13: Power Supply

    Product overview 3.2.2 Power supply The panel PC is supplied with a nominal voltage of 24 V. The connection to the power supply is made via the 4-pin M12 voltage socket (X101). The main supply voltage is applied between PIN 1 (24 V) and PIN 3 (0 V) of the socket.
  • Page 14: Ethernet Rj45

    Product overview 3.2.3 Ethernet RJ45 The panel PC has two Gigabit LAN ports (X102, X103). The 100Base-T and 1000Base-T Ethernet standards enable the connection of corresponding network components and data rates of 100/1000 Mbit/s. The required speed is selected automatically. The RJ45 connection technology with twisted-pair cables is used. The maximum length of the cable connection is 100 m.
  • Page 15: Name Plate

    Product overview Name plate The name plate provides information about the panel PC equipment. The name plate shown here serves only as an example. xxxxxxx xxxxxxxxxxxx xxxxxxxxxxxx Fig. 6: Name plate Table 7: Legend: name plate CP77xx Description Model: The last four digits indicate the device generation. Serial number (BTN) Date of manufacture Mainboard...
  • Page 16: Key Functions

    Product overview Key functions You can order your panel PC with different versions of the front laminate. You can choose between a panel PC without buttons and a panel PC with different button configurations. Please refer to the current price list for specific ordering options.
  • Page 17 Product overview Opening the properties window of a selected object Esc = close dialog box, cancel operations Set printed character to the cursor position … Function keys = functions of the keys determined by the software Special keys = special keys with LED that can be controlled by the TwinCAT automation software Einschub Einschub...
  • Page 18: Commissioning

    If you, as the user, require additional protection for the touch screen against dirt and scratching, for example due to dirty hands, this can be achieved with a Beckhoff protective film. The film provides short-term protection for a few days.
  • Page 19: Transport And Unpacking

    6. In case of discrepancies between the package contents and the order, or in case of transport damage, please inform Beckhoff Service (see Chapter 10.1 Service and Support). Mounting Dimensions The dimensions of the control panel can be found on the Beckhoff website: https://www.beckhoff.com/de- de/support/downloadfinder/technische-zeichnungen/. All dimensions are in mm. Also see about this 2 Technical data [} 33]...
  • Page 20 Commissioning The cabling of the panel PC in the control cabinet must be done in accordance with the standard EN 60204-1:2006 PELV = Protective Extra Low Voltage: • The PE conductor (protective earth) and the "0 V" conductor of the voltage source must be on the same potential (connected in the control cabinet).
  • Page 21: Grounding The Panel Pc

    Commissioning 4.3.1 Grounding the panel PC Potential differences are minimized and electrical currents are diverted to the ground through grounding or potential equalization of electronic devices. This is to prevent dangerous touch voltages and electromagnetic interference. On the rear side of the panel PC there is the protective conductor connection PE (see Fig. 7), which ensures both the protective earthing of the PC and the functional earthing.
  • Page 22: Connecting Cables And Power Supply

    Commissioning 4.3.2 Connecting cables and power supply NOTICE Incorrect connection procedure Incorrect procedure when connecting the cables and the power supply can cause hardware damage. • Follow the documented procedure for connecting the cables and the power supply. • Always connect all cables first and only then switch on the power supply. •...
  • Page 23: Beckhoff Device Manager

    • User name: Administrator • Password: 1 You also have the option of using the Beckhoff Device Manager to remotely configure the industrial PC via a web browser. More detailed information is available in the Beckhoff Device Manager manual. First start Beckhoff Device Manager When your industrial PC is booted for the first time, the Beckhoff Device Manager also starts automatically for the first time.
  • Page 24: Fig. 9 Beckhoff Device Manager - Start Page

    Secure passwords Strong passwords are an important prerequisite for a secure system. Beckhoff supplies the device images with standard user names and standard passwords for the operating system. It is imperative that you change these. Controllers are shipped without a password in the UEFI/BIOS setup. Beckhoff recommends assigning a password here as well.
  • Page 25: Decommissioning

    Decommissioning Decommissioning CAUTION Risk of electric shock Disconnecting the panel PC during a thunderstorm can lead to electric shock. • Never disconnect the cables of the panel PC during a thunderstorm. NOTICE Hardware damage due to power supply A connected power supply can cause damage to the device during disassembly. •...
  • Page 26: Maintenance

    You can clean the front screen of the device during operation. In order to avoid inadvertent touch entries when doing this, you must first set the device to "Cleaning Mode" with the help of the Beckhoff Control Tool. The Beckhoff Control Tool does not start automatically when the device starts up. Proceed as follows to activate the "Cleaning Mode"...
  • Page 27: Fig. 10 Select "Cleaning Mode

    Maintenance Fig. 10: Select "Cleaning Mode" You can set the duration for which the panel PC should remain in "Cleaning Mode". The period can be set between 5 and 120 seconds. Right-click the sun symbol again and click "Options". Now select the appropriate duration (see Fig.).
  • Page 28: Table 9 Device Component Replacement Recommendations

    NOTICE Use of incorrect spare parts The use of spare parts not ordered from Beckhoff Service can lead to unsafe and faulty operation. • Only use spare parts that you have ordered from Beckhoff Service. Beckhoff devices are manufactured from components of the highest quality and robustness. They are selected and tested for best interoperability, long-term availability and reliable function under the specified environmental conditions.
  • Page 29: Replacing The Battery

    Replace the battery with R/C (BBCV2), order number RC2032, nominal voltage 3 V. Using any other battery may cause fire or explosion. • Only replace the battery with a replacement battery from Beckhoff Service. • When replacing the battery, make sure that the polarity is correct.
  • Page 30: Fig. 13 Battery Change

    Maintenance The device does not contain a lithium-ion battery. The motherboard battery is a CR2032 lithium-metal cell. It is used to supply power to the clock integrated on the motherboard. If the battery is depleted or missing, the date and time are displayed incorrectly. Table 10: Technical data of the battery Battery type Electrical properties (at 20 °C)
  • Page 31: Replacing The Storage Media

    If you want to exchange a storage medium according to Beckhoff's recommendation, you must copy the data from the old to the new storage medium. You can use the Beckhoff Service Tool (BST) for this purpose. BST is a graphical backup and restore program for PCs with a Windows operating system. You can create an image of your operating system and use it to back up the operating system.
  • Page 32: Troubleshooting

    No function of the panel PC No power supply to the panel PC Check the power supply cable Other cause Call Beckhoff Service The panel PC does not boot fully BIOS setup settings are incorrect Check BIOS setup settings (load...
  • Page 33: Technical Data

    Supply voltage 22-30 V (24 V power supply unit, NEC class 2) Power consumption Data sheet for calculating power consumption and power loss in the download finder - Data sheets: http://www.beckhoff.com/downloadfinder Protection rating IP65 Vibration resistance (sinusoidal EN 60068-2-6: 10 to 58 Hz: 0.035 mm vibration) 58 to 500 Hz:...
  • Page 34: 10 Appendix

    33415 Verl Germany Phone: + 49 5246/963-0 email: info@beckhoff.de The addresses of the worldwide Beckhoff branches and agencies can be found on our website at http:// www.beckhoff.com/. You will also find further documentation for Beckhoff components there. Version: 3.4 CP77xx...
  • Page 35: Approvals

    Appendix 10.2 Approvals Your device has at least the following approvals: • CE • EAC • UKCA • FCC You will find all other applicable approvals on the name plate of your device. FCC approvals for the United States of America FCC: Federal Communications Commission Radio Frequency Interference Statement This device was tested and complies with the limits for a digital device of class A, according part 15 of the FCC regulations.
  • Page 36 Ethernet interface pin numbering ....................Fig. 6 Name plate........................... Fig. 7 CP77xx_protective conductor connection..................Fig. 8 Beckhoff Device Manager - Change passwords ................Fig. 9 Beckhoff Device Manager – Start page ..................Fig. 10 Select "Cleaning Mode" ....................... Fig. 11 Configuration "Cleaning Mode"...
  • Page 37 List of tables List of tables Table 1 Legend CP77xx structure......................Table 2 RS232 pin assignment ......................... Table 3 Voltage socket pin assignment CP77xx-0040................Table 4 Voltage socket pin assignment CP77xx-0050................Table 5 Ethernet interface pin assignment....................Table 6 Connecting cable CP77xx......................Table 7 Legend: name plate CP77xx......................
  • Page 39 More Information: www.beckhoff.com/cp77xx Beckhoff Automation GmbH & Co. KG Hülshorstweg 20 33415 Verl Germany Phone: +49 5246 9630 info@beckhoff.com www.beckhoff.com...

Table of Contents