Table of Contents

Advertisement

Quick Links

Manual | EN
CP6606
Panel PC
2/17/2022 | Version: 2.0

Advertisement

Table of Contents
loading

Summary of Contents for Beckhoff CP6606

  • Page 1 Manual | EN CP6606 Panel PC 2/17/2022 | Version: 2.0...
  • Page 3: Table Of Contents

    Disconnecting the power supply and cables ................... 27 Disassembly and disposal ....................... 28 6 Maintenance ............................. 29 Cleaning ............................ 29 Maintenance ............................ 29 6.2.1 Replacing the battery.......................  31 6.2.2 Replacing the storage medium .................. 32 7 Troubleshooting ............................ 33 8 Technical data............................ 34 9 Appendix .............................. 35 Service and support......................... 35 Approvals............................ 36 CP6606 Version: 2.0...
  • Page 4 Table of contents Version: 2.0 CP6606...
  • Page 5: Notes On The Documentation

    Copyright © Beckhoff Automation GmbH & Co. KG. Publication of this document on websites other than ours is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.
  • Page 6: For Your Safety

    Exclusion of liability Beckhoff shall not be liable in the event of non-compliance with this documentation and thus the use of the devices outside the documented operating conditions. Description of safety symbols The following safety symbols are used in these operating instructions.
  • Page 7: Fundamental Safety Instructions

    • the operating instructions are in good condition and complete, and always available for reference at the location where the products are used. CP6606 Version: 2.0...
  • Page 8: Notes On Information Security

    For your safety Notes on information security The products of Beckhoff Automation GmbH & Co. KG (Beckhoff), insofar as they can be accessed online, are equipped with security functions that support the secure operation of plants, systems, machines and networks. Despite the security functions, the creation, implementation and constant updating of a holistic security concept for the operation are necessary to protect the respective plant, system, machine and networks against cyber threats.
  • Page 9: Product Overview

    Product overview Product overview The built-in Panel PC CP6606 is designed for installation in the front of a control cabinet or control housing and can be used in a variety of ways in machine and system engineering. The Panel PC is suitable for universal use in PLC as well as Motion Control applications in small and medium-sized machines, plants or buildings.
  • Page 10: Structure

    Fig. 2: CP6606_Structure Table 1: Key: C6606 structure Component Description Clamping lever Mounting the Panel PC in the panel of the control cabinet Display and touch screen glass Operation of the Panel PC Access to interfaces Interfaces on the underside Version: 2.0 CP6606...
  • Page 11: Interface Description

    22 V should be present at the power supply plug of the Panel PC so that the PC remains switched on in the event of voltage fluctuations. The plug is included in the delivery. You can obtain a replacement plug from your Beckhoff Sales using the following ordering option: • C9900-P927: power supply connector for Panel PC CP66xx CP6606 Version: 2.0...
  • Page 12: Ethernet Rj45

    The Panel PC has two USB 2.0 interfaces (X104, X105). They are used to connect peripheral devices with USB interfaces. X104 1 2 3 4 X105 1 2 3 4 Fig. 5: CP6606_USB interface pin numbering Table 4: USB interface pin assignment Connection Shield Vbus Version: 2.0 CP6606...
  • Page 13: Rs232

    The serial interface (X107) is fed out via a 9-pin standard DSUB connector. The signals comply with the RS232 standard. X107 Fig. 6: CP6606_RS232 interface pin numbering Table 5: RS232 pin assignment Signal Description Data Carrier Detect Receive Data Transmit Data Data Terminal Ready Ground Data Set Ready Request to Send Clear to Send Rind Indicator CP6606 Version: 2.0...
  • Page 14: Status Leds

    Table 7: Meaning of the PWR LED Color Flashing interval Meaning Green Steadily lit Connection to power supply unit with power supply switched on Flashing rapidly Error in the power supply Flashing slowly No or faulty MicroSD card inserted Version: 2.0 CP6606...
  • Page 15: Name Plate

    Product overview Name plate The name plate provides information about the Panel PC equipment. Fig. 8: CP6606_name plate CP6606 Version: 2.0...
  • Page 16: Table 8 Key: Name Plate Cp6606

    Product overview Table 8: Key: name plate CP6606 Description Model: the last four digits indicate the device generation. Serial number Date of manufacture Mainboard Power supply Main memory Storage medium Display 10 Touch screen 11 MAC addresses of the Ethernet interfaces...
  • Page 17: Commissioning

    Beckhoff Service (see Chapter 9.1 Service and Support [} 35]). Control cabinet installation The Panel PC CP6606 is designed for installation in the front of a control cabinet in machine and system engineering. The environmental conditions specified for operation must be observed (see chapter 8 Technical data [} 34]).
  • Page 18: Dimensions

    Figure 9 shows the dimensions of the Panel PC without push button extension. 1 91 1 77 Fig. 9: CP6606_dimensions Figure 10 shows the dimensions of the Panel PC with push button extension. Fig. 10: CP6606_dimensions push button extension Version: 2.0 CP6606...
  • Page 19: Installation In The Control Cabinet

    2. Loosen the clamping levers with a 2.5 mm Allen key (sections A and B). 3. Fold out the clamping levers 90° (section C). 4. Retighten the clamping levers with the Allen key (section D). Fig. 11: CP6606_control cabinet installation CP6606 Version: 2.0...
  • Page 20: Wall Installation With Wall Mounting Frame

    Wall installation with wall mounting frame NOTE Reduced operating temperature range Installing the CP6606 in the wall mounting frame reduces the operating temperature range to a maximum of 45 °C. • Ensure that the maximum operating temperature range of the Panel PC is not exceeded.
  • Page 21: Fig. 12 Cp6606_Wall Installation With Wall Mounting Frame

    Commissioning Fig. 12: CP6606_Wall installation with wall mounting frame CP6606 Version: 2.0...
  • Page 22: Connecting The Panel Pc

    5-pin connection strip and a strain relief housing with cable tie. If you require a replacement for the voltage connector or the strain relief housing, you can order these from Beckhoff Sales. Assembly of the supply cable First mount the plug on the cable as follows: 1.
  • Page 23: Fig. 13 Cp6606_Assembly Of Strain Relief Housing

    1. Use your fingers to bend the latching lugs on the lower part slightly outward (see Fig. 14). 2. Lever the upper part off the lower part. 3. Cut the cable tie. Fig. 14: CP6606_Disassembly of strain relief housing CP6606 Version: 2.0...
  • Page 24: Grounding The Panel Pc

    To do this, the Panel PC must comply with certain protection requirements. The Panel PC has EMC interference immunity according to EN 61000-6-2. The EMC interference emission of the device meets the requirements of EN 61000-6-4. The functional earth is necessary for the EMC of the device. Version: 2.0 CP6606...
  • Page 25: Connecting Cables And Power Supply

    4. Screw the voltage connector to the voltage socket. 5. Connect the PC to your external 24 V power supply. 6. Switch on the 24 V power supply. 7. Measure the voltage on the power supply plug of the PC. CP6606 Version: 2.0...
  • Page 26: Switching The Panel Pc On And Off

    Since there is a risk of data loss if the Panel PC is switched off incorrectly, assign the rights advisedly. A user who is not allowed to terminate the software should not be allowed to switch off the Panel PC. Version: 2.0 CP6606...
  • Page 27: Decommissioning

    Proceed as follows to disconnect the cables from the Panel PC: 1. Make a note of the wiring configuration, if you wish to restore it with another device. 2. Disconnect all data transfer cables from the Panel PC. 3. Finally, disconnect the ground connection. CP6606 Version: 2.0...
  • Page 28: Disassembly And Disposal

    3. To reattach the clamping levers to the housing, retighten them with the Allen key (section D). Fig. 16: CP6606_Removal from the control cabinet Disposal of the Panel PC When disposing of the Panel PC, be sure to observe the national electronic waste regulations. Version: 2.0 CP6606...
  • Page 29: Maintenance

    Repair Only the manufacturer may repair the device. If a repair should be necessary, contact Beckhoff Service (see Chapter 9.1 Service and Support [} 35]). Cleaning...
  • Page 30: Table 9 Replacement Recommendations For Pc Components

    Motherboard battery 5 years Beckhoff is excluded from liability in the event of possible damage occurring during maintenance work. In order to avoid damage caused by electrostatic discharge when replacing device components, protective measures are recommended. Below are some suggestions.
  • Page 31: Replacing The Battery

    Replace the battery with R/C (BBCV2), order number C2032, nominal voltage 3 V. Using any other battery may cause fire or explosion. • Only replace the battery with a replacement battery from Beckhoff Service. • When replacing the battery, make sure that the polarity is correct.
  • Page 32: Replacing The Storage Medium

    If you want to exchange a storage medium according to Beckhoff's recommendation, you must copy the data from the old to the new storage medium. You can use the Beckhoff Service Tool (BST) for this purpose. The BST is a graphical backup and restore program for Industrial PCs with a Windows operating system. You can create an image of your operating system and use it to back up the operating system.
  • Page 33: Troubleshooting

    No power supply to the Panel PC Check the power supply cable Cable not connected 1. Correctly connect the cable 2. Call Beckhoff Service Panel PC boots, software starts, The cause of the error is the Call the machine or software...
  • Page 34: Technical Data

    Technical data Technical data Table 12: Technical data Product designation CP6606-0001-0020 Weight 0.9 kg Supply voltage 20.4-30 V (24 V power supply unit, NEC class 2) Power consumption max. 12 W Protection rating Front IP54, rear IP20 Vibration resistance (sinusoidal EN 60068-2-6: 10 ...
  • Page 35: Appendix

    Telephone: + 49 (0) 5246/963-0 Fax: + 49 (0) 5246/963-198 email: info@beckhoff.de The addresses of the worldwide Beckhoff subsidiaries and agencies can be found on our website at http:// www.beckhoff.com/. You will also find further documentation for Beckhoff components there.
  • Page 36: Approvals

    FCC approvals for Canada FCC: Canadian Notice This device does not exceed the class A limits for radiation, as specified by the Radio Interference Regulations of the Canadian Department of Communications. Version: 2.0 CP6606...
  • Page 37 CP6606_Disassembly of strain relief housing ................Fig. 15 CP6606_Grounding bolt for functional earthing................Fig. 16 CP6606_Removal from the control cabinet ................. Fig. 17 CP6606_Access to battery and storage medium ................ Fig. 18 CP6606_Replacing the battery....................Fig. 19 CP6606_Replacing the storage medium ..................CP6606 Version: 2.0...
  • Page 38 Table 5 RS232 pin assignment......................... Table 6 Meaning of the TC LED ....................... Table 7 Meaning of the PWR LED......................Table 8 Key: name plate CP6606......................Table 9 Replacement recommendations for PC components ..............Table 10 Technical data of the battery .......................
  • Page 40 More Information: www.beckhoff.com/CP6606 Beckhoff Automation GmbH & Co. KG Hülshorstweg 20 33415 Verl Germany Phone: +49 5246 9630 info@beckhoff.com www.beckhoff.com...

Table of Contents