Table 3-7: Expansion I/O LED functions
Expansion I/O Module LED
TX/RX
LINK/ACT
Ethernet Switch Port 1, 2, 3
Frequency/Digital outputs
The meter has three user-configurable outputs that can be configured for either a
Frequency output or Digital output (FODO).
FODO1 (eight possible parameter configurations) [Type 2] [Type 4]
FODO2 (eight possible parameter configurations) [Type 2] [Type 4]
FODO3 (eight possible parameter configurations) [Type 2] [Type 4]
FODO4 (eight possible parameter configurations) [Type 4]
FODO5 (eight possible parameter configurations) [Type 4]
FODO6 (eight possible parameter configurations) [Type 4]
Frequency or Digital Outputs (FODO1, FODO6) source options ∼ Group 1
FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
Frequency output 1A is the A Phase of Frequency output 1 content (Uncorrected volume
flow rate, Corrected volume flow rate, Average flow velocity, Average speed of sound,
Energy flow rate, Mass flow rate)
Frequency output 1B is the B Phase of Frequency output 1
Frequency output 2A is based on frequency content (Actual - Uncorrected Flow Rate)
Frequency output 2B is based on frequency content and Frequency 2B Phase
Digital output 1A is based on Digital output1A content (Frequency Output 1Validity and
Flow Direction)
Digital output 1B is based on Digital output1B content (Frequency Output 1Validity and
Flow Direction)
Digital output 2A is based on Digital output 2A content (Frequency Output 1Validity and
Flow Direction)
Digital output 2B is based on Digital output 2B content (Frequency Output 1Validity and
Flow Direction)
Frequency or Digital Outputs (FODO2, FODO3, FODO4, FODO5) source options ∼
Group 2
FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
Installation manual
(DI1Mode must be set to Frequency/Digital Output 6 to enable FODO6)
Function
RX/TX signal (Port B/C for
RS485 or RS232 communication)
receiving and transmitting data
Link and Activity indicator
for each Ethernet switch
port
Separate indicator for each
Ethernet switch port
Electrical installation
October 2023
LED
Flashing Orange - RX
Flashing Green - TX
Flashing Green when Ethernet
activity present
61