7.2

Replacing the batteries/fuse VRLA AGM 12Ah

-0V
+24V
-0V
WARNING:
Make sure that no charger is
connected to the battery unit.
WARNING:
Caution when handling the
batteries and their terminals.
For fuse replacement only follow numbers 1-5
and figure i.
1. Place the battery unit securely on a table.
2. Open the battery enclosure by loosening the four
screws of the right gable enclosure. Leave the
cables connected to the gable enclosure.
3. Remove the short side fixing plate by loosen its
screw. Remove the long side fixing plate.
4. Carefully slide out the batteries from the battery
enclosure.
+24V
7
Electrical hazard!
Electrical hazard!
6
5
4
3
5. At the blade receptables of the cables
detach the fuse and its holder from the batteries.
(For fuse replacement, figure i; replace the fuse in
the holder. Reconnect cables. Remount by follow
numbers 4-2).
6. At the blade receptables of the cables
detach the cables to the connector of the battery
enclosure. Remove the old
batteries.
Arrange the new batteries with the contacts facing
each other. Connect the cables in figure 5 and
figure 6 to the new batteries. Remount by follow
figure 4-2.
7. WARNING Avoid short circuit, keep distance be-
tween batteries terminals.
i
1
2
29