5.9.1 Declaration of
Compressed Cfg
Compressed Cfg
X X X X
/
X X X X
A B C D
E
A
Batteri type
B
Handcontrol
C
Machine type
D
Motor function
E-H End stop
I-L
24V
26
/
X X X X
F
G H
I
J
K L
1= VRLA AGM, 2= LiFePO4
1=Stepless
1=Single, 2=Telescope (two swiches), 3=Telescope basic
(one swich), 4=Parallel, 5=Separate
1=Standard
No end swich: E=0, F=0, G=0, H=0
J100-2 input, Up (accessories): E=1, F=0, G=0, H=0
J100-3 input, Down (accessories): E=0, F=1, G=0, H=0
J101-2 input, Up (tools): E=0, F=0, G=1, H=0
J101-1 input, Down (tools): E=0, F=0, G=0, H=1
J104-1 output, Always off: I=0, J=0, K=0, L=0
J104-1 output, Follow input J100-1: I=0, J=1, K=0, L=0
J104-1 output, Invert input J100-1: I=1, J=1, K=0, L=0
J104-1 output, Follow input J100-2: I=0, J=2, K=0, L=0
J104-1 output, Invert input J100-2: I=2, J=2, K=0, L=0
J104-1 output, Follow input J100-3: I=0, J=3, K=0, L=0
J104-1 output, Invert input J100-3: I=3, J=3, K=0, L=0
J104-1 output, Follow input J100-4: I=0, J=4, K=0, L=0
J104-1 output, Invert input J100-4: I=4, J=4, K=0, L=0
J104-1 output, Follow input J100-6: I=0, J=6, K=0, L=0
J104-1 output, Invert input J100-6: I=6, J=6, K=0, L=0
J104-1 output, Always on: I=1, J=6, K=0, L=0
J104-2 output, Inactive: N/A