Pronomic 90P Original Instructions Manual

Pronomic 90P Original Instructions Manual

Parts for stationary lifter

Advertisement

Parts for Stationary
lifter
(90P/125P130P/175P/
225P)
Original instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 90P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pronomic 90P

  • Page 1 Parts for Stationary lifter (90P/125P130P/175P/ 225P) Original instructions...
  • Page 2 It is important that you read and understand the manual before assembly. Do you have any questions? – Please contact the distributor or the manufacturer. Pronomic AB Visiting address: Postal address: Domherrevägen 15 Box 5504 192 55 Sollentuna 192 05 Sollentuna...
  • Page 3: Table Of Contents

    5.2.5 Lift column ............................7 Trouble shooting.......................... 9 Technical specifications ...................... 9 Load diagram ........................10 90P Setup ........................... 10 125P Setup ..........................11 130P Setup ..........................12 175P Setup ..........................13 225P Setup ..........................14 DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY ......15...
  • Page 4: Description Of The Parts

    Damage due to misuse or incorrect use of the equipment will void the warranty. 1.2 Components The stationary lifter consists of a number of modules. The locations of these are shown in the image on the next page. Please contact Pronomic for information regarding part numbers.   Column Remote control ...
  • Page 5 ________________________________________________________________________________ 2 – Stationary lifter (90/125/130/175/225P)
  • Page 6: Assembly

    2 Assembly Protective footwear should be used when assembling the stationary lifter, to prevent injuries if parts are dropped. It is important that the modules are installed according to this specifications. Confirm the design of the structure that the stationary lifter is mounted to. Consider the load diagrams starting on page 10.
  • Page 7: Disassembly And Scrapping

    To disassemble the stationary lifter, follow the instructions in section Assembly, but in reverse order. When the stationary lifter is due for scrapping the machine should be handed in to a recycling centre or Pronomic to ensure reuse and safe handling of all parts. ________________________________________________________________________________ 4 – Stationary lifter (90/125/130/175/225P)
  • Page 8: Using The Stationary Lifter

    3 Using the Stationary lifter If the load is left on the stationary lifter for some time it may be necessary to lower the load before it can be raised. 3.1 Remote control The load carrier is raised and lowered by pressing the buttons on the remote control. The remote control has either two or four buttons and is used as shown below.
  • Page 9: Storage And Transport

    4.2 Storage and transport During storage and transport the remote control and motor cable should be disconnected. The parts should be secured during transport to avoid the risk of damage. 4.3 Loading and unloading The user is responsible for ensuring that the stationary lifter is loaded correctly. The centre of gravity of the goods should always be centred on the load carrier and as close to the column as possible, for maximum stability.
  • Page 10: Maintenance

    5.2. For example: Using the stationary lifter for 300 lift actions per day will shorten the interval from every year to every six month. Only spare parts supplied or approved by Pronomic may be used. After disassembly/assembly of the column or load carrier a load test should be performed, see section Assembly.
  • Page 11 Put the lift screw back and tighten the screws. Check the coupling, by making sure the sleeve and the hub located inside the column and inside the cross-member are intact and in working order. Put the lift column back and perform load test, see section Assembly. ________________________________________________________________________________ 8 –...
  • Page 12: Trouble Shooting

    If problems arise, some guidance is provided below. If the problem persists after action has been taken – Please contact service technician or Pronomic. If the load carrier does not move at all, or very slowly: •...
  • Page 13: Load Diagram

    7 Load diagram 7.1 90P Setup ________________________________________________________________________________ 10 – Stationary lifter (90/125/130/175/225P)
  • Page 14: 125P Setup

    7.2 125P Setup ________________________________________________________________________________ 11 – Stationary lifter (90/125/130/175/225P)
  • Page 15: 130P Setup

    7.3 130P Setup ________________________________________________________________________________ 12 – Stationary lifter (90/125/130/175/225P)
  • Page 16: 175P Setup

    7.4 175P Setup ________________________________________________________________________________ 13 – Stationary lifter (90/125/130/175/225P)
  • Page 17: 225P Setup

    7.5 225P Setup ________________________________________________________________________________ 14 – Stationary lifter (90/125/130/175/225P)
  • Page 18: Declaration Of Incorporation Of Partly Completed Machinery

    DECLARATION OF INCORPORATION OF PARTLY COMPLETED MACHINERY Manufacturer Pronomic AB Box 5504 192 05 Sollentuna Sweden Parts for stationary lifter  90P  125P  130P  175P  225P Model Serial number Static load test Applied EC directives: 2006/42/EC...
  • Page 19: Installation

    INSTALLATION PRONOMIC AB is not responsible for installation of the partly completed machine. The partly completed machine has been installed according to the instructions in this manual and the safety and limitations has been considered. ……………………………………… Place, date …………………………………………………………….. ……………………………………………...
  • Page 20 ________________________________________________________________________________ 17 – Stationary lifter (90/125/130/175/225P)

This manual is also suitable for:

125p130p175p225p

Table of Contents