10 OPTIONS
INSTALLATION
TCXO UNIT (SO-2)
1
Remove the transceiver bottom cover (9 screws).
2
Remove the shield covering the control board
(2 screws).
7
3
CAREFULLY remove the 3 flat cables from the
control board, and lift the board.
4
CAREFULLY remove the 3 coaxial cable
connectors (CN2, CN3, CN4) and the 4-pin
connector (CN1) from the PLL board.
Do not pull
on the wires to remove CN1.
Remove the 7
screws holding the PLL board.
t
rere
|
Tt.
55
5
Lift the PLL board.
6
Position and solder the SO-2.
Use a law power
iron (25W) and rosin core solder.
Do not overheat
the PC board and lift foil traces, and do not use
excess solder and cause a solder bridge (short).
Clip the SO-2 leads flush to the PC board after
soldering.
7
Cut the jumper wires at W1 and We on the PLL
board.
Re-position the PLL board.
Tighten the 7 screws to secure the PLL board.
Reconnect the 3 coaxial cable connectors (CN2,
CN3, CN4) and the 4-pin connector (CN1).
10 Reinstall the control board and CAREFULLY
reconnect the flat cables.
41 Reinstall the shield using the 2 screws.
12 Reinstall the bottom cover (9 screws).
Note:
Do not pinch your fingers nor any wires while
reassembling.

Advertisement