2. If needed, remove the non-hot-swap power supply. See "Removing the non-hot-swap power supply" on
page 82.
3. Install the new non-hot-swap power supply into the chassis so that the four screw holes in the new non-
hot-swap power supply are aligned with the corresponding holes in the rear of the chassis. Then, install
the four screws to secure the new non-hot-swap power supply in place.
Figure 65. Installing the non-hot-swap power supply
4. Connect cables to the new non-hot-swap power supply. Then, properly route the cables and secure the
cables with the cable clips and ties in the chassis.
Intrusion switch
This topic applies only to server models that have the intrusion switch installed.
• "Removing the intrusion switch" on page 83
• "Installing the intrusion switch" on page 84
Removing the intrusion switch
To remove the intrusion switch, do the following:
1. Prepare your server and remove the server cover. See "Preparing your server in advance and removing
the server cover" on page 49.
2. Locate the intrusion switch. Then, disconnect the cable from the intrusion switch.
3. Press the two tabs on the intrusion switch towards each other and carefully push the intrusion switch
outward at the same time to remove it from the frame.
2
1
.
Chapter 5
Replacing hardware
83