9.13

Save and load the camera settings

The camera has camera setting save function, camera setting including factory default loads function.
The camera has below two camera settings.
Default: The factory default settings (This setting cannot change)
UserSetX: Over writeable camera settings (X: 0 to 7)
These camera settings load from ROM to register in RAM on camera and camera settings save to ROM.
The camera settings saving and loading is controllable with Parameters (UserSetSelector, UserSetDefault), and
commands (UserSetLoad, UserSetSave) in UserSetControl category of GenICam.
The details of parameters and functions are in table below:
GenICam Parameters
UserSetSelector
UserSetLoad
UserSetSave
UserSetDefault
Camera
Setting
Selector
UserSetSelector
Setting Procedure
1. Selects "UserSetX" at "UserSetSelector"
2. Execute "UserSetSave"
STC-LBS34U3V-SWIR
Product Specifications and User's Guide
IEnumeration Type
Select "Default" or "UserSetX"
UserSetLoad or UserSetSave process for selected settings.
ICommand Type
The camera settings load from ROM to register in RAM.
ICommand Type
The camera settings at register in RAM save to ROM.
IEnumeration Type
Select which settings ("Default or UserSetX) load automatically when camera
power is on.
This selection saves automatically.
ROM
UserSetX
ROM
Default
When UserSetSave is executing,
camera settings at register in RAM
are saved to ROM that is selected at
UserSetSelector.
Caution:
UserSetSave cannot execute when "Default"
was selected at "UserSetSelector"
No. 22S036-00