Image Acquisition And Camera Operational Modes (Genicam); Free Run - Omron STC-LBS34U3V-SWIR Product Specifications And User's Manual

Usb3 vision swir cmos camera
Table of Contents

Advertisement

7

Image Acquisition and Camera Operational Modes (GenICam)

Please refer to another chapter for method of switching Trigger.
GenICam Parameters
TriggerSelector
TriggerMode
TriggerSource
ExposureMode
Please refer to IO function for (*) Line.
7.1

Free Run

Free run mode outputs image continuously.
In order to run Free run Mode, all trigger functions must be set to OFF at TriggerMode.
Exposure time determines ExposureMode. When ExposureMode is turned off, frame exposure will complete.
When ExposureMode is set to Timed, ExposureTime value will be set as exposure time.
露光
Exposure
Image Out
映像出力
(*) The camera is set to Free run mode as default mode.
STC-LBS34U3V-SWIR
Product Specifications and User's Guide
IEnumeration Type
Select Trigger function
IEnumeration Type
Select ON / OFF which was selected function on TriggerSelector
On: Trigger function ON, Off: Trigger function Off
IEnumeration Type
Set Trigger Source which was selected function on TriggerSelector
Software: Trigger control through TriggerSoftware command
LineN: Trigger control through hardware trigger (N: Line number)
IEnumeration Type
Select Exposure mode
ExposureTime
No. 22S036-00
22/54

Advertisement