Output Port Function; Line Source - Omron STC-LBS34U3V-SWIR Product Specifications And User's Manual

Usb3 vision swir cmos camera
Table of Contents

Advertisement

8.2

Output Port Function

This function sets Output to LineMode, and then Line is assigned as output.
The following functions can be assigned when IO port is used as output signal port.
The following list shows configurable functions available through LineSource.
The function that describes as "Enable" on "Changeable Polarity" is configurable polarity on LineInverter
(true, false).
No.
1)
2)
3)
4)
5)
6)
7)
8)
1) Off (Disable)
Disable the output signal.
2) User Output (General Output)
High or Low level signal that sets on software is output.
3) Trigger Out (Trigger Output)
The trigger signal that added "TriggerOutDelay (Output pulse delay time)" and "TriggerOutOnTime (Output
pulse width)" is output.
4) Exposure End Out (Exposure End)
"TriggerOutOnTime (Output pulse width)" activation time signal with set "TriggerOutDelay (Output pulse
delay time)" is output when expose was finished.
5) Frame End Out (Sensor Readout End)
"TriggerOutOnTime (Output pulse width)" activation time signal with set "TriggerOutDelay (Output pulse
delay time)" is output when sensor read out was finished.
6) Transfer End Out (Transfer End Output)
"TriggerOutOnTime (Output pulse width)" activation time signal with set "TriggerOutDelay (Output pulse
delay time)" is output when one frame image transferring from camera was finished.
7) Strobe Out (Strobe Output)
"StrobeOutOnTime (Output pulse width)" activation time signal with set "StrobeOutDelay (Strobe output
delay time)" is output when trigger signal is received.
STC-LBS34U3V-SWIR
Product Specifications and User's Guide
Function Name
Off (Default)
User Output
Trigger Out
Exposure End Out
Frame End Out
Transfer End Out
Strobe Out
Exposure Active
Changeable
Polarity
-
-
Enable
Enable
Enable
Enable
Enable
Enable
No. 22S036-00
29/54

Advertisement

Table of Contents
loading

Table of Contents