Batching Function - Siemens SITRANS FC720 Operating Instructions Manual

Coriolis c
Table of Contents

Advertisement

Batching function

In addition to water cut, the function can calculate: Net oil mass flow, net water mass
flow, net oil volume flow, net water volume flow and net corrected oil volume flow.
Advanced concentration measurement
The advanced concentration measurement (option Gxx) is recommended for more
complex applications, such as for liquids that interact.
Following is a table that lists possible pre-configured concentrations. The desired data
sets must be requested by the customer to the Siemens sales organization at the time
the order is placed. The customer is responsible to ensure chemical compatibility of the
material of the wetted parts with the measured chemicals. For strong acids or oxidizers
which attack steel pipes, a variant with wetted parts made of Ni alloy C-22/2.4602 is
necessary.
Set
Fluid A / B
G01
Sugar / Water
G02
NaOH / Water
1)
G03
KOH / Water
G04
NH
NO
/ Water
4
3
G05
NH
NO
/ Water
4
3
G06
HCl / Water
1)
G07
HNO
/ Water
3
G09
H
O
/ Water
1)
2
2
Ethylene glycol /
G10
1)
Water
G11
Starch / Water
G12
Methanol / Water
G20
Alcohol / Water
G21
Sugar / Water
G30
Alcohol / Water
G37
Alcohol / Water
1)
We recommend using devices with wetted parts made of nickel alloy C22. Contact the
Siemens sales organization about availability.
Maximum 4 Gxx option sets can be ordered for one device simultaneously.
20.3 Batching function
Batching and filling processes are typical applications in different industries as food and
beverage, cosmetic, pharmaceutical, chemical and oil & gas.
SITRANS FC offers an integrated "Batching function" to automatize the task. A "self-
learning" algorithm optimizes the process and allows high accurate results.
The function supports two filling modes:
Concentra
Unit Temperatu
tion range
re range
in °C
0 – 85
°Bx
0 – 80
0 – 54
WT%
0 – 100
1 – 55
WT%
54 – 100
1 – 50
WT%
0 – 80
20 – 70
WT%
20 – 100
22 – 34
WT%
20 – 60
50 – 67
WT%
10 – 60
30 – 75
WT%
4.5 – 43.5
10 – 50
WT%
-20 – 40
33 – 42.5
WT%
35 – 45
35 – 60
WT%
0 – 40
55 – 100 VOL%
10 – 40
40 – 80
°Bx
75 – 100
66 – 100
WT%
15 – 40
66 – 100
WT%
10 – 40
Density
Data source for density data
range
in kg/l
PTB... Messages 100 5/90: "The
density of watery sucrose solutions
0.97 – 1.45
after the introduction of the
international temperature scale of
1990 (ITS1990)" Table 5
D´Ans-Lax, Handbook for chemists
0.95 – 1.58
and physicists Vol.1, 3rd edition,
1967
D´Ans-Lax, Handbook for chemists
1.01 – 1.58
and physicists Vol.1, 3rd edition,
1967
0.97 – 1.24 Table of density data on request
1.04 – 1.33 Table of density data on request
D´Ans-Lax, Handbook for chemists
1.08 – 1.17
and physicists Vol.1, 3rd edition,
1967
1.26 – 1.40 Table of density data on request
1.00 – 1.20 Table of density data on request
1.005 – 1.085 Table of density data on request
1.14 – 1.20 Table of density data on request
0.89 – 0.96 Table of density data on request
0.76 – 0.94 Table of density data on request
1.15 – 1.35 Table of density data on request
0.77 – 0.88 Standard Copersucar 1967
0.772 – 0.885 Brazilian Standard ABNT
A5E52748387-AA, 2023/09
FC7x0
Advanced functions
167 / 180

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans fc740

Table of Contents