MCi MC8 Crusader Maintenance Manual page 403

Table of Contents

Advertisement

MAINTENANCE
Crusader
MC-8
[ ,. 0
,_1_6 _-3_2A _ _
DAIE_J_on_ua~ry_,
_l 9_75_] ·
MANUAL
SUPERHEAT ADJUSTMENT
To provide accurate superheat adjustment on the
driver's evaporator and main evaporator expansion
valves the following procedure should be followed:
Fittings are provided on both evaporators to adjust for
TEMPERATURE
PRESSURE
GAUGE
EXPANSION
VALVE
proper superheat.
Before checking superheat in the driver's evaporator
and main evaporator, turn the driver's evaporator and
main evaporator expansion valve adjustment control
counterclockwise all the way and turn the adjustment 11
full turns clockwise.
TH IS END OF HOSE
MUST HAVE CHECK
VALVE DEPRESSER
-t'
CHECK VALVE IS
---
INSTALLED IN
FITTING
.
~QUALIZER LINE
ADJUSTMENT
CONTROL
l 9-10-460 FITTING
REMOTE
BULB
TEMPERATURE
GAUGE
Before Checking Open System
SUCTION LINE
AT EVAPORATOR
INSERT PROBE OF
THERMOMETER AT
REMOTE BULB IN
THIS AREA
INSTALLATION OF FITTING AT EXPANSION VALVE

Advertisement

Table of Contents
loading

Table of Contents