Cas Menu - Cascata; Play - Ferroli EGEA TECH 200 HT Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 128
EGEA TECH
Behavior
Description
ANTI-LEGIONELLA enabled
on with
but not running
steady light
ANTI-LEGIONELLA logic
flashing light
running
3.9.14 CAS menu ­ CASCATA
Value
Description
Cascade level selected in manual mode
c01
(0= min, 1= med, 2= max)
Enable cascade function (0= disabled, 1=
c02
enabled)
c03
Unit address
c04
Number of units present in the cascade
Number of units switched on with min.
c05
level
Number of units switched on with med
c06
level
c07
Number of units switched on with max
c08
Unit priority rotation time
NOTA: for all the units that must operate in CASCATA, pa­
rameter c02 must be set = 1.
MASTER
Once the cascade function has been activated, it is possible to set
the unit in Master mode by setting parameter c03 to the value 1
To function correctly, the cascade function requires the fol-
lowing parameters to be set on the MASTER:
c01: with this parameter it is possible, if the function is enabled,
to select the desired cascade level
c02: set the parameter = 1
c03: set the parameter = 1 (MASTER)
c04: the number of units present in the cascade (master +
number of slaves)
c05: The number of units to keep on when the minimum ope-
rating level is requested
c06: The number of units to keep on when the medium opera-
ting level is requested
c07: The number of units to keep on when the maximum ope-
rating level is requested
NOTA: parameters c04, c05, c06, c07, c08 must be set only
on the MASTER unit. If set on the SLAVE units they have no
effect.
SLAVE
To function correctly, the cascade function requires the fol-
lowing parameters to be set on the SLAVE:
c02: set the parameter = 1
c03: set the parameter = from 2 to 8 (SLAVE)
200 HT - 260 HT
Active mode
The unit continues to work in the mode
set by the user
The unit will be placed in BOOSTER
status and the setpoint will be raised
to 62°C
Unit of
default min max Level
measure
-
2
0
-
0
0
-
2
1
-
2
2
-
1
1
-
2
2
-
2
2
days
1
1
cod. 3540000420 - Rev. 03 - 09/2023
NOTE:
the
fies the position of the Slave inside the cascade.
It is therefore necessary to make sure that the assigned value
has not already been assigned to another unit and, above all,
that the water heater is identified with an increasing number,
from 2 up to the number of units present (maximum 8 units).
Example of setting parameter c03 for a cascade of 4 units:
unit 1 (master) c03=1
unit 2 (slave 2) c03=2
2
U / I
unit 3 (slave 3) c03=3
1
I
unit 4 (slave 4) c03=4
8
I
8
I
c08: The parameter defines the rotation time expressed in days
8
I
to define the period of cyclic rotation of operation of the various
8
I
units. The cyclical rotation has the purpose of guaranteeing a
8
I
use and therefore a balanced wear in terms of operating time
30
I
of all the units. Higher values of the parameter do not affect this
function but only involve longer times to reach it: it is therefore
advisable not to modify this parameter.
3.9.15 UtS Menu – BRAND, RANGE, MODEL, SERIAL NUMBER
DISPLAY
From this menu it will be possible to view the identifying values of
the unit, such as:
Menu
Liv. 1
Uts
U0
1) To interpret these values, contact technical assistance.
.
value
set
in
parameter
Liv. 2
Description
U00
Brand
(1)
U01
Range
(1)
U02
Model
(1)
U03
Serial Number
c03
identi-
Parameters
1, ... 3
1
1, ... 8
Rif. par. fig. 60
EN