3480DEC18-MP2SD-ASI18
High Density MPEG-2 SD Decoder
3.2.4. ASI Faults
This tab is divided into two windows: Faults and Trap Enable.
3.2.4.1.
Faults
•
TS Sync Error: The presence of the sync byte (x47) is monitored here, this indicator will stay
green as long as a sync byte is present, if a sync byte cannot be detected this indicator will turn
red.
•
TS ID Error: This indicator checks the TS ID present within the PAT against the value entered
by the user under the ASI Input Control tab; if the values match the indicator will remain green,
otherwise it will turn red.
•
Number of Programs: This indicator checks the Number of Programs present within the PAT
against the value entered by the user under the ASI Input Control tab; if the values match the
indicator will remain green, otherwise it will turn red.
•
ASI Fault Condition 1: The conditions that will trigger this indicator can be configured under
the ASI Fault Trigger.
3.2.4.2.
Trap Enable
Using the trap enable section the user can enable or disable traps from being sent. To enable any of
the traps/alarms simply click the check box that corresponds to the alarm you wish to enable.
Page 12
Figure 3-6: ASI Faults
Revision 0.1