6. Setting up the control protocol

The impression X5 IP Bar 1000 can be controlled via:
● USITT512 DMX over a standard DMX cable link using the fixture's 5-pin XLR
connectors,
● GLP's wireless iQ.Mesh technology.
● LumenRadio CRMX (supplied). The integrated GLP FPO (Flexible Protocol Option)
port allows the installation of an optional control protocol module. The impression
X5 IP Bar 1000 is supplied with a LumenRadio CRMX module installed as standard.
Your GLP supplier can give you details of other control protocol modules that may
be available.
This section explains how to configure the fixture to use one of these control data
protocols.
Note: The control protocol settings are not affected if you apply a Fixture Settings
Load User Settings
are returned to factory defaults if you apply a Load Factory Defaults command in the
main menu.
DMX
The fixture is set up for control via a standard DMX cable link by default.
If the control data protocol has been changed and you want to return to DMX control
over a standard DMX cable link, open the menus in the fixture's control panel and
make the following adjustments:
In the main menu in the fixture's control panel, open DMX Address and give the
fixture a suitable DMX address.
In the Protocol Setup → Data In menu, set the control protocol to DMX.
iQ.Mesh
If you want to control the fixture via GLP iQ.Mesh:
Open the menus in the fixture's control panel.
In the Protocol Setup → Data In menu, set the control protocol to iQ.Mesh.
LumenRadio CRMX
A LumenRadio CRMX module is installed as standard at the impression X5 IP Bar 1000's
FPO port when the fixture is supplied.
If you want to control the fixture via LumenRadio CRMX, open the menus in the fixture's
control panel and make the following adjustments:
Open the menus in the fixture's control panel.
In the Protocol Setup → Data In menu, set the control protocol to CRMX.
Setting Defaults command in the fixture's control panel, but they
Rev. 20230928-01
X5 IP Bar 1000
31