Operation; H1F Shaft Rotation Direction; H1F Loop Flushing Shuttle Spool - Danfoss H1F 080 Service Manual

H1f bent axis fixed displacement motor
Hide thumbs Also See for H1F 080:
Table of Contents

Advertisement

Service Manual
H1F Bent Axis Fixed Displacement Motors, Size 080

Operation

H1F Shaft rotation direction

H1F Loop flushing shuttle spool

14 |
©
Danfoss | December 2023
Shaft rotation direction is determined with a view from the shaft end.
Flow into port A
Flow into port B
An integral loop flushing shuttle spool is used to separate system A and system B pressures.
System delta pressure will cause the shuttle spool to shift, allowing the low side system pressure to flow
to the loop flushing relief valve.
Legend:
A
System loop A
B
System loop B
LFRV
to loop flushing relief valve
W
Warning
Unintended vehicle or machine movement hazard.
Excessive motor loop flushing flow may result in the inability to build required system pressure in some
conditions. Maintain correct charge pressure under all conditions of operation to maintain pump control
performance in hydrostatic systems.
CCW
CW
Clockwise
Counterclockwise
A
B
L2
P003 437
AX465363259664en-000102